Part Number 74HC193-Q100
Manufacturer nexperia
Description Presettable synchronous 4-bit binary up/down counter
Published Jul 29, 2019
Detailed Description 74HC193-Q100; 74HCT193-Q100 Presettable synchronous 4-bit binary up/down counter Rev. 3 — 8 September 2021 Product da...
Datasheet PDF File 74HC193-Q100 PDF File

74HC193-Q100
74HC193-Q100


Overview
74HC193-Q100; 74HCT193-Q100 Presettable synchronous 4-bit binary up/down counter Rev.
3 — 8 September 2021 Product data sheet 1.
General description The 74HC193-Q100; 74HCT193-Q100 is a 4-bit synchronous binary up/down counter.
Separate up/down clocks, CPU and CPD respectively, simplify operation.
The outputs change state synchronously with the LOW-to-HIGH transition of either clock input.
If the CPU clock is pulsed while CPD is held HIGH, the device counts up.
If the CPD clock is pulsed while CPU is held HIGH, the device counts down.
Only one clock input can be held HIGH at any time to guarantee predictable behavior.
The device can be cleared at any time by the asynchronous master reset input (MR).
It may also be loaded in parallel by activating the asynchronous parallel load input (PL).
The terminal count up (TCU) and terminal count down (TCD) outputs are normally HIGH.
When the circuit has reached the maximum count state of 15, the next HIGH-to-LOW transition of CPU causes TCU to go LOW.
TCU remains LOW until CPU goes HIGH again, duplicating the count up clock.
Likewise, the TCD output goes LOW when the circuit is in the zero state and the CPD goes LOW.
The terminal count outputs duplicate the clock waveforms and can be used as the clock input signals to the next higher-order circuit in a multistage counter.
Multistage counters are not fully synchronous, since there is a slight delay time difference added for each stage that is added.
The counter may be preset by the asynchronous parallel load capability of the circuit.
Information on the parallel data inputs (D0 to D3), is loaded into the counter.
This information appears on the outputs (Q0 to Q3) regardless of the conditions of the clock inputs when the parallel load (PL) input is LOW.
A HIGH level on the master reset (MR) input disables the parallel load gates.
It overrides both clock inputs and sets all outputs (Q0 to Q3) LOW.
If one of the clock inputs is LOW during and after a reset or load operation, t...