DatasheetsPDF.com

JTL3048T0512

XP Power
Part Number JTL3048T0512
Manufacturer XP Power
Description DC-DC Converter
Published Dec 24, 2019
Detailed Description DC DC 30 Watts JTL Series xppower.com • 4:1 Input Range • High Power Density • Single, Dual and Triple Outputs • High ...
Datasheet PDF File JTL3048T0512 PDF File

JTL3048T0512
JTL3048T0512


Overview
DC DC 30 Watts JTL Series xppower.
com • 4:1 Input Range • High Power Density • Single, Dual and Triple Outputs • High Efficiency Up to 91% • Remote On/Off • 1600 VDC Isolation • 3 Year Warranty Specification Input Input Voltage Range Input Current Input Reflected Ripple Input Filter Undervoltage Lockout Input Surge • 24 V (9-36 VDC), 48 V (18-75 VDC) • See table • 20 mA pk-pk through 12 µH inductor • Pi network • 24 V models: ON 8.
6 V, OFF 7.
9 V typical 48 V models: ON 17.
8 V, OFF 16 V typical • 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms Output Output Voltage • See table Output Voltage Trim • ±10% on single outputs models only Minimum Load • No minimum load required for single and dual output models, 10% required on all outputs for triple output models Line Regulation • ±0.
2% max for single and dual output models, ±1.
0% main, ±5% auxiliary for triple output models Load Regulation • Single output models: ±0.
5% max Dual output models: ±1% max balanced outputs Triple output models: ±1% max main, ±5% auxiliaries Cross Regulation • ±5% for dual and triples output (see note 2) Setpoint Accuracy • ±1% (±5% for triple auxiliaries) Start Up Time • 30 ms typical Ripple & Noise • 100 mV or 1% pk-pk, whichever is greater single & dual output models, 50/75 mV pk-pk main/auxiliary outputs of triple output models, 20 MHz bandwidth (see note 3) Transient Response • 3% max deviation, recovery to within 1% in <250 µs for a 25% load change Temp.
Coefficient • 0.
02%/°C Overvoltage Protection • 3.
3 V models: 3.
9 V typical 5 V models: 6.
2 V typical 12 V models: 15 V typical 15 V models: 18 V typical ±5 V models: ±6.
2 V typical ±12 V models: ±15 V typical ±15 V models: ±18 V typical Overload Protection • >150% of full load Short Circuit Protection • Trip & restart (hiccup mode), auto recovery Overtemperature Protection • 115 °C typical Remote On/Off • On = Logic High (>3.
0) or Open Off = Logic Low (<1.
2 V) or short pin 2 to 3 Maximum C...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)