Detailed Description DATASHEET HIP0060 1.5A, 50V Quad Low Side Power Driver with Serial Bus Control and Fault Protection FN4045 Rev 0.00 Ju...
Datasheet PDF File HIP0060 PDF File

HIP0060
HIP0060


Overview
DATASHEET HIP0060 1.
5A, 50V Quad Low Side Power Driver with Serial Bus Control and Fault Protection FN4045 Rev 0.
00 July 1997 Features • Quad NDMOS Output Drivers in a High Voltage Power BiMOS Process • Over-Stress Protection - Each Output - Over-Current Limiting.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1.
5A Min - Internal Zener Drain-to-Gate Over-Voltage Clamp Protection .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
50V Typ - Thermal Shutdown Protection - Open-Load Detection • Low Quiescent Current .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10mA Max • Serial Diagnostic Link with SPI Bus • Diagnostic Interrupt Fault Flag • 5V CMOS Logic Input Control • Common Reset for Fault Bits and Output Drivers • Ambient Operating Temperature Range .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
-40oC to 125oC Applications • Automotive and Industrial Systems • Fuel Injection Drivers • Solenoids, Relays and Lamp Drivers • Logic and P Controlled Drivers • Robotic Controls Description The HIP0060 is a 5V logic controlled Quad Low Side Power Driver.
The outputs are individually protected for over-current (OC), over-temperature (OT) and over-voltage (OV).
If an OC short circuit in the output load is sensed (IS) in one output power driver, that output current will be independently limited while the other outputs remain in operation.
Over-current is limited by direct gate feedback.
Over-voltage protection is provided by a drain-to-gate zener diode that clamps inductive switching pulses.
The output drivers are individually controlled through a Gate Control Latch.
Temperature is sensed at each output.
If a thermal fault exists, a status flag is set and the output is latched off.
Open-load (OL) and over-temperature (OT) faults sets a status flag bit as diagnostic output to the SPI bus.
For all fault bits (8), an ORed one-shot interrupt signal is output to the INT pin.
An RST reset clears the fault flags and disables all outputs while active.
The Serial Peripheral Interface (SPI) bus pins are the Serial ...