DatasheetsPDF.com

ADM3058E

Analog Devices
Part Number ADM3058E
Manufacturer Analog Devices
Description CAN-FD Transceiver
Published Nov 2, 2020
Detailed Description Data Sheet 5.7 kV rms, Signal Isolated, High Working Voltage, CAN FD Transceiver with ±15kV IEC ESD ADM3058E FEATURES ...
Datasheet PDF File ADM3058E PDF File

ADM3058E
ADM3058E


Overview
Data Sheet 5.
7 kV rms, Signal Isolated, High Working Voltage, CAN FD Transceiver with ±15kV IEC ESD ADM3058E FEATURES 5.
7 kV rms signal isolated CAN FD transceiver 1500 V peak and dc working voltage to DIN VDE 0884-11 1.
7 V to 5.
5 V supply and logic side levels 4.
5 V to 5.
5 V supply on bus side ISO 11898-2:2016-compliant CAN FD Data rates up to 12 Mbps for CAN FD Low maximum loop propagation delay: 155 ns Extended common-mode range: ±25 V Bus fault protection (CANH, CANL): ±40 V ESD protection on the CANH and CANL bus pins ≥±8 kV IEC 61000-4-2 contact discharge ≥±15 kV IEC 61000-4-2 air discharge Passes EN 55022, Class B by 6 dB Safety and regulatory approvals (pending) UL: 5700 V rms for 1-minute per UL 1577 CSA Component Acceptance 5A at 5.
7 kV rms IEC 60601 and IEC 61010 VDE Certificates of Conformity DIN VDE V 0884-11 (VDE V 0884-11):2017-01 VIORM = 1500 V peak High common-mode transient immunity: >50 kV/μs Industrial operating temperature range: −40°C to +125°C APPLICATIONS CANOpen, DeviceNet, and other CAN bus implementations Industrial automation Process control and building control Transport and infrastructure GENERAL DESCRIPTION The ADM3058E is a 5.
7 kV rms isolated controller area network (CAN) physical layer transceiver with a high performance, basic feature set.
The ADM3058E fully meets the CAN flexible data rate (CAN FD) ISO 11898-2:2016 requirements and is further capable of supporting data rates as high as 12 Mbps.
The device employs Analog Devices, Inc.
, iCoupler® technology to combine a 2-channel isolator and a CAN transceiver into a single small outline integrated circuit (SOIC) surface-mount package.
The ADM3058E is a fully isolated solution for CAN and CAN FD applications.
The ADM3058E provides isolation between the CAN controller and physical layer bus.
Safety and FUNCTIONAL BLOCK DIAGRAM VDD1 VDD2 ADM3058E TXD DIGITAL ISOLATOR CAN TRANSCEIVER DOMINANT TIMEOUT RXD THERMAL SHUTDOWN CANH CANL GND1 Figure 1.
GND2 20135-001 regulato...