CPC1593GS

IXYS
Part Number CPC1593GS
Manufacturer IXYS
Description Normally Open OptoMOS Relay
Published Jan 13, 2021
Detailed Description INTEGRATED CIRCUITS DIVISION Parameter Load Voltage Load Current On-Resistance (max) Input Control Current Rating 600 ...
Datasheet PDF File CPC1593GS PDF File

CPC1593GS
CPC1593GS


Overview
INTEGRATED CIRCUITS DIVISION Parameter Load Voltage Load Current On-Resistance (max) Input Control Current Rating 600 ±120 35 2 Units VP mA  mA Features • Integrated Active Current-Limit with Over-Voltage Protection • Thermal Regulation • 600VP Blocking Voltage • Guaranteed Turn-On: 2mA Input Control Current • 3750Vrms Input/Output Isolation • Low Drive Power Requirements • Arc-Free With No Snubbing Circuits • No EMI/RFI Generation • Flammability Rating UL 94 V-0 Applications • In-Rush Current Control • Heating, Ventilation, Air Conditioning Control (HVAC) • Security Systems • Power Supplies • Home Appliances • IC Equipment Protection • Instrumentation • Medical Equipment—Patient/Equipment Isolation • Aerospace • Industrial Controls Block Diagram LOAD Gate Drive Control + Current Limit V and F Over-Voltage - Protection Thermal Management LOAD CPC1593 Single-Pole, Normally Open OptoMOS® Relay Integrated Current Limit with Voltage and Thermal Protection Description The CPC1593 is a normally open (1-Form-A) Solid State Relay that incorporates load current limiting with over-voltage protection and thermal management.
This self-resetting triple protection scheme protects not only the CPC1593’s load, but also the CPC1593 itself, thus creating a highly effective switching mechanism that is designed to survive in the harshest operating environments.
Over-voltage protection is activated when the voltage across the switch is greater than 21V and the device is in current limit.
The over-voltage protection deactivates the switch while allowing a restricted load current of less than 100A to flow.
When the voltage across the switch falls below the over-voltage threshold, the switches reactivate.
If the fault persists, then these responses will repeat.
The CPC1593 is designed for use in AC environments where fault conditions can persist for long periods of time, and where, upon removal of the fault, return to normal operation is expected.
The CPC1593 is designed ...