DatasheetsPDF.com

RF058-XXXXX-XXXXXX-X

Samtec
Part Number RF058-XXXXX-XXXXXX-X
Manufacturer Samtec
Description CABLE
Published Jan 26, 2021
Detailed Description REVISION Q DO NOT SCALE FROM THIS PRINT DESIGNED & DIMENSIONED IN MILLIMETERS[INCHES] RF058-XXXXX-XXXXXX-XXXX FIG 2 C...
Datasheet PDF File RF058-XXXXX-XXXXXX-X PDF File

RF058-XXXXX-XXXXXX-X
RF058-XXXXX-XXXXXX-X


Overview
REVISION Q DO NOT SCALE FROM THIS PRINT DESIGNED & DIMENSIONED IN MILLIMETERS[INCHES] RF058-XXXXX-XXXXXX-XXXX FIG 2 CABLE STRIPPING DIMENSIONS PER CONFIGURATIONS (SEE TABLE 1)(SEE NOTES 12,13,14,15) "A" mm C "B" mm "C" mm "D" mm C "E" mm C CABLE CALLOUT 058: CCA-058 (RG-58 COAXIAL CABLE) END 1 CONNECTOR -05SR: TNC-P-C-XX-SR-C10 (SEE SHEET 2) -06SP: NTPE-P-C-XX-ST-C10 (SEE SHEET 2) -01BJ: SMA-J-C-XX-ST-B10 (SEE SHEET 2) -01SB: SMA-J-C-XX-ST-S10 (SEE SHEET 2) -01SP: SMA-P-C-XX-ST-C10 (SEE SHEET 2) END 1 PLATING OPTION 1: GOLD ALL COMPONENTS 2: GOLD/NICKEL 3: ALTERNATE GOLD / NICKEL 7.
ALTERNATE GOLD MEDIUM/ GOLD FLASH (SEE SHEET 2 FOR PLATING SPECIFICS) OVERALL CABLE LENGTH MILLIMETERS OF CABLE 0100 MIN.
(SEE NOTE 8 & 9) END 2 PLATING OPTION 1: GOLD ALL COMPONENTS 2: GOLD/NICKEL 3: ALTERNATE GOLD / NICKEL 7.
ALTERNATE GOLD MEDIUM/ GOLD FLASH (SEE SHEET 2 FOR PLATING SPECIFICS) (LEAVE BLANK FOR -SING OR -XXXXXX END 2 PREPARATION) END 2 CONNECTOR OR PREPARATION -05SR: TNC-P-C-XX-SR-C10 (SEE SHEET 2) -06SP: NTPE-P-C-XX-ST-C10 (SEE SHEET 2) -01BJ: SMA-J-C-XX-ST-B10 (SEE SHEET 2) -01SB: SMA-J-C-XX-ST-S10 (SEE SHEET 2) -01SP: SMA-P-C-XX-ST-C10 (SEE SHEET 2) -SING: SINGLE ENDED (ONE END ONLY, SEE NOTE 11) -XXXXXX: STRIPPED AND TINNED (THIS END ONLY- SEE NOTES 11-16 & SHEET 2, FIG.
3) (SEE FIG.
2) "C" FORMAT: X.
X mm (SEE FIG.
2) "B" FORMAT: X.
X mm (SEE FIG.
2) "A" FORMAT: X.
X mm DO NOT LEAVE ANY SPACE BLANK, EACH MUST CONTAIN A NUMERIC CHARACTER 0 THRU 9.
NOTES: 1.
C REPRESENTS A CRITICAL DIMENSION 2.
CABLE CUT LENGTH: = (LENGTH: XXXX) - (SUBTRACTOR FOR END 1) - (SUBTRACTOR FOR END 2).
(SEE TABLE 1 FOR SUBTRACTORS) C 3.
ASSEMBLY TO BE 100% TESTED FOR OPENS & SHORTS C 4.
ASSEMBLY TO BE 100% HI-POT TESTED PER TABLE 1 AND THE TEST VOLTAGE FOR THE ASSEMBLY SHOULD BE SET TO THE END OPTION WITH THE LOWEST TEST VOLTAGE RATING.
5.
AFTER FINAL ELECTRICAL TESTS, LABEL EACH CABLE ASSEMBLY WITH 1 LABEL -ET 6.
CRITICALS ON CONNECTOR PRINTS TO BE CHECKED IN PROCESS 7.
FINIS...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)