DatasheetsPDF.com

GP2Y0A21YK

Sharp
Part Number GP2Y0A21YK
Manufacturer Sharp
Description Distance Measuring Sensor
Published Dec 20, 2021
Detailed Description GP2Y0A21YK/GP2Y0D21YK GP2Y0A21YK/ GP2Y0D21YK I Features 1. Less influence on the color of reflective objects, reflectiv...
Datasheet PDF File GP2Y0A21YK PDF File

GP2Y0A21YK
GP2Y0A21YK


Overview
GP2Y0A21YK/GP2Y0D21YK GP2Y0A21YK/ GP2Y0D21YK I Features 1.
Less influence on the color of reflective objects, reflectivity 2.
Line-up of distance output/distance judgement type Distance output type (analog voltage) : GP2Y0A21YK Detecting distance : 10 to 80cm Distance judgement type : GP2Y0D21YK Judgement distance : 24cm (Adjustable within the range of 10 to 80cm [Optionally available]) 3.
External control circuit is unnecessary 4.
Low cost I Applications 1.
TVs 2.
Personal computers 3.
Cars 4.
Copiers I Absolute Maximum Ratings (Ta=25˚C, VCC=5V) Parameter Symbol Rating Unit Supply voltage VCC −0.
3 to +7 V Output terminal voltage VO −0.
3 to VCC +0.
3 V Operating temperature Topr −10 to +60 ˚C Storage temperature Tstg −40 to +70 ˚C General Purpose Type Distance Measuring Sensors I Outline Dimensions (Unit : mm) #4.
5 φ3.
2 hole 37 29.
5 #20±0.
1 R3.
75 3.
75 Light emitter side 10.
1 14.
75 7.
5 4.
15 16.
3 Light detector side R3.
75 6.
3 Lens case 2 8.
4 7.
2 13 18.
9−+00.
.
35 φ3.
2 hole Connector 1.
2 Made by J.
S.
T.
MFG, 3.
3 CO.
, LTD.
S3B-PH PWB 2-1.
5 13.
5 13 ❈ The dimensions marked # are described the dimensions of lens center position.
❈ Unspecified tolerance : ±0.
3mm Terminal connection 1 VO 2 GND 3 VCC Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.
com/ecg/ I Recommended Operating Conditions Parameter Symbol Rating Unit Operating supply voltage VCC 4.
5 to +5.
5 V GP2Y0A21YK/GP2Y0D21YK I Electro-optical Characteristics Parameter Distance measuring range GP2Y0A21YK Output terminal voltage GP2Y0D21YK Difference of output voltage GP2Y0A21YK Distance characteristics of output GP2Y0D21YK Symbol ∆L VO VOH VOL ...