Description Linear Hall-Effect Current Sensor
Published Jan 8, 2023
Detailed Description MCS1802 3.3V, Linear Hall-Effect Current Sensor with ±2.5% Accuracy Over Temperature DESCRIPTION The MCS1802 is a linea...
Datasheet PDF File MCS1802 PDF File

MCS1802
MCS1802


Overview
MCS1802 3.
3V, Linear Hall-Effect Current Sensor with ±2.
5% Accuracy Over Temperature DESCRIPTION The MCS1802 is a linear Hall-effect current sensor for AC or DC current sensing.
The Hall array is differential, which cancels out any stray magnetic field.
A primary conductor with a low resistance allows current to flow close to the IC, which contains high-accuracy Hall-effect sensors.
This current generates a magnetic field that is sensed at two different points by the integrated Hall-effect transducers.
The magnetic field difference between these two points is then converted into a voltage that is proportional to the applied current.
A spinning current technique is used for a low and stable offset.
The galvanic isolation between the pins of the primary conductive path and the sensor leads allows the MCS1802 to replace opto-isolators or other isolation devices.
The MCS1802 requires a minimal number of readily available, standard external components.
The device’s small footprint saves board area and makes it well-suited for space-constrained applications.
The MCS1802 is available in an SOIC-8 package.
FEATURES • 3.
3V Single Supply • Immune to External Magnetic Fields by Differential Sensing • 2.
2kVRMS Minimum Isolation Voltage • Operating Temperature: -40°C to +125°C • 0.
9mΩ Internal Conductor Resistance • ±5A to ±50A Bi-directional Range • Adjustable Bandwidth up to 100kHz • 4μs Output Rising Time • Ratiometric Output from Supply Voltage • Output Proportional to AC or DC Currents • Factory-Trimmed for Accuracy • No Magnetic Hysteresis • Available in an SOIC-8 Package APPLICATIONS • Motor Control • Automotive Systems • Load Detection and Management • Switch-Mode Power Supplies • Over-Current Fault Protection All MPS parts are lead-free, halogen-free, and adhere to the RoHS directive.