Texas Instruments
Part Number 65HVD251
Manufacturer Texas Instruments
Description Industrial CAN Bus Transceiver
Published May 10, 2023
Detailed Description Product Folder Sample & Buy Technical Documents Tools & Software Support & Community SN55HVD251, SN65HVD251 SLLS545...
Datasheet PDF File 65HVD251 PDF File

65HVD251
65HVD251


Overview
Product Folder Sample & Buy Technical Documents Tools & Software Support & Community SN55HVD251, SN65HVD251 SLLS545G – NOVEMBER 2002 – REVISED OCTOBER 2015 SNx5HVD251 Industrial CAN Bus Transceiver 1 Features •1 Drop-In Improved Replacement for the PCA82C250 and PCA82C251 • Bus-Fault Protection of ±36 V • Meets or Exceeds ISO 11898 • Signaling Rates(1) up to 1 Mbps • High Input Impedance Allows up to 120 Nodes on a Bus • Bus Pin ESD Protection Exceeds 14 kV HBM • Unpowered Node Does Not Disturb the Bus • Low-Current Standby Mode: 200-µA Typical • Thermal Shutdown Protection • Glitch-Free Power-Up and Power-Down CAN Bus Protection for Hot-Plugging • DeviceNet Vendor ID #806 (1) The signaling rate of a line is the number of voltage transitions that are made per second expressed in bps (bits per second).
2 Applications • CAN Data Buses • Industrial Automation • SAE J1939 Standard Data Bus Interface • NMEA 2000 Standard Data Bus Interface D1 GND 2 Block Diagram Overtemperature Sensor Vcc (3) VCC (3) SLOPE CONTROL and MODE LOGIC VCC (3) VCC/2 VREF (5) 8 RS Driver 7 CANH VCC 3 6 CANL R4 5 VREF 3 Description The HVD251 is intended for use in applications employing the Controller Area Network (CAN) serial communication physical layer in accordance with the ISO 11898 Standard.
The HVD251 provides differential transmit capability to the bus and differential receive capability to a CAN controller at speeds up to 1 megabits per second (Mbps).
Designed for operation in harsh environments, the device features cross-wire, overvoltage and loss of ground protection to ±36 V.
Also featured are overtemperature protection as well as –7-V to 12-V common-mode range, and tolerance to transients of ±200 V.
The transceiver interfaces the single-ended CAN controller with the differential CAN bus found in industrial, building automation, and automotive applications.
Rs, pin 8, selects one of three different modes of operation: high-speed, slope control, or low-power mode...