DatasheetsPDF.com

MD-113

Tyco
Part Number MD-113
Manufacturer Tyco
Description High Performance Double-Balanced Mixer
Published Apr 29, 2005
Detailed Description High Performance Double-Balanced Mixer, 5 - 1000 MHz V 3.00 MD-113 Features Low Cost Flatpack Conversion Loss: 7 dB Ty...
Datasheet PDF File MD-113 PDF File

MD-113
MD-113


Overview
High Performance Double-Balanced Mixer, 5 - 1000 MHz V 3.
00 MD-113 Features Low Cost Flatpack Conversion Loss: 7 dB Typical Impedance: 50 Ohms Nominal Maximum Input Power: 300 mW max.
@ 25°C, Derated linearly to 85°C @ 3.
2 mW/°C n IF Port Current: 50 mA Max.
n MIL-STD-883 Screening Available n n n n FP-2 Description Transformers convert the LO and RF paths to balanced lines connecting to a low barrier, Schottky diode ring quad.
These transformers help provide excellent isolation between ports.
Conversion Loss is low.
The direct connection of the IF port to the diode quad allows these mixers to be used as phase detectors and bi-phase modulators.
Pin Configuration Pin No.
1 2 3 4 Function GND GND GND IF Pin No.
5 6 7 8 Function LO GND GND RF Electrical Specifications1: TA = -55°C to +85°C Parameter Frequency Range Conversion Loss Test Conditions RF, LO Ports IF Port Frequency 5 - 1000 DC - 1000 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz LO to RF 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz — Units MHz MHz dB dB dB dB dB dB dB dB dB dB dB dB — mV 1 dB Compression 1 dB Desensitization dBm dBm Min — — — — — 35 30 25 30 25 20 25 20 15 — — — — Typ — — — — — — — — — — — — — — — <2 0 -2 Max — — 7.
5 7.
5 8.
0 — — — — — — — — — — — — — Isolation LO to IF RF to IF DC Polarity DC Offset RF Input Negative 1.
All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance.
High Performance Double-Balanced Mixer, 5 - 1000 MHz Electrical Specifications: TA = -55°C to +85°C Parameter SSB Noise Figure Typical Two Tone IM Ratio Test Conditions Within 1 dB of Conversion Loss Max.
With –10 dBm input, each input 25 MHz and 35 MHz IF Frequency — 100 - 550 MHz 550 - 800 MHz 800 - 1000 MHz Units — dB dB dB Min — — — — Typ — >47 >38 >44 MD-113 V 3.
00 Max — — — — Typical Performance Curves Conversion Loss (RF = -5 dBm, LO = +7 dBm) 8 50 Isolation LO - RF LO - IF RF - IF ...



Similar Datasheet