DatasheetsPDF.com

M7612

Mosdesign
Part Number M7612
Manufacturer Mosdesign
Description PIR Controller
Published Jul 23, 2005
Detailed Description MOSDESIGN SEMICONDUCTOR CORP. PIR CONTROLLER M7612 PIR CONTROLLER GENERAL DESCRIPTION The M7612 is a PIR ( passive i...
Datasheet PDF File M7612 PDF File

M7612
M7612


Overview
MOSDESIGN SEMICONDUCTOR CORP.
PIR CONTROLLER M7612 PIR CONTROLLER GENERAL DESCRIPTION The M7612 is a PIR ( passive infra-red ) controller , using analog mixing digital design technique and manufactures by CMOS Process which can either drive TRIAC or RELAY depending on user’s choice.
With special noise immunity technique , M7612 is the most stable PIR controller you can find on the market.
More than this , there are few components needed in its application circuit which can reduce material cost and increase competitive.
FEATURES • High noise immunity.
• Drive either RELAY or TRIAC.
• Adjustable light on duration.
• TRIAC can be either shunt or serial connected.
• PIR input.
• CDS input.
• Auto change on / auto mode by bonding option.
• 16 pin DIP or SOP package.
APPLICATIONS • PIR light controller, Motion Detector, Alarm system, Auto-door bell.
PIN ASSIGNMENT M7612P UOU1 NII1 II1 VREF VSS TB QTEST TCI 8 9 1 16 UOU2 NII2 II2 VDD ZCD RELAY TRIAC CDS 1/9 2003-12-02 MOSDESIGN SEMICONDUCTOR CORP.
PIR CONTROLLER M7612 PIR CONTROLLER PIN DESCRIPTION Pin No 1 2 3 4 5 Pin Name UOU1 NII1 II1 VREF VSS First stage OP amp output.
First stage OP amp positive input.
First stage OP amp negative input.
Stable reference voltage.
System ground.
Time base for: The delay time of receiving PIR signal to sent a pulse to trigger TRIAC or a high signal to trigger relay.
The delay time = R * C * 32.
6 TB The PIR signal patented and accepted only if the signal cycle greater than R * C * 768.
When state of RELAY or TRIAC is changing form active into inactive mode.
It takes more than R * C * 4069 , then system is able to receive PIR signal again.
10K < R < 1M Ohm 100p F ≦ C < 0.
1uf ( Reference Diagram 1 ) 7 QTEST For testing only.
To set up the timing of how long TRIAC or RELAY is active.
During the period , if the system receives the PIR signal , then it restarts counting the timing again.
The flash cycle show the beginning of auto mode.
8 TCI Note:width of TRIAC pulse = R * C *...