DatasheetsPDF.com

CSNB121

Honeywell
Part Number CSNB121
Manufacturer Honeywell
Description Solid State Sensors Closed Loop Current Sensors
Published Feb 10, 2007
Detailed Description www.DataSheet4U.com Solid State Sensors Closed Loop Current Sensors CSN Series CATALOG NUMBER SYSTEM PLEASE NOTE: Thi...
Datasheet PDF File CSNB121 PDF File

CSNB121
CSNB121


Overview
www.
DataSheet4U.
com Solid State Sensors Closed Loop Current Sensors CSN Series CATALOG NUMBER SYSTEM PLEASE NOTE: This matrix is intended only to aid you in identifying sensor catalog listings.
It is not all-inclusive, and must not be used to form new listings.
Example: CSNA111 CSN Closed Loop Current Sensor Current Range (Peak/RMS nom.
) A ±70 A/50 A rms nom.
B ±100 A/50 A rms nom.
C ±90 A/50 A rms nom.
D ±22 A/15 A rms nom.
E ±36 A/25 A rms nom.
F ±150 A/100 A rms nom.
J ±600 A/300 A rms nom.
K ±1200 A/500 A rms nom.
L ±600 A/300 A rms nom.
M ±1200 A/500 A rms nom.
P ±90 A/50 A rms nom.
R ±200 A/125 A rms nom.
T ±150 A/50 A rms nom.
Supply Voltage 1 ±15 V 2 ±13 V 3 ±5 V 4 ±12 V to 18 V 5 ±15 V to 24 V 6 ±12 V to 15 V Coil Characteristics 1 1:1000 turns/90 ȉ @ 70°C 2 1:2000 turns/160 ȉ @ 70°C 3 1:2000 turns/130 ȉ @ 70°C 4 1:1000 turns/50 ȉ @ 70°C 5 1:1000 turns/110 ȉ @ 70°C 6 1:1000 turns/30 ȉ @ 70°C 7 1:2000 turns/80 ȉ @ 70°C 8 1:2000 turns/25 ȉ @ 70°C 9 1:5000 turns/50 ȉ @ 85°C Housing Material 1 Polycarbonate/ABS blend PDFINFO p a g e - 0 6 0 FEATURES ɀ Current sensing up to 1200 amps ɀ Measures AC, DC and impulse currents ɀ Lowest cost/performance ratio ɀ Rapid response, no overshoot ɀ High overload capacity ɀ High level of electrical isolation between primary and secondary circuits ɀ Small size and weight CLOSED LOOP SENSORS Closed loop current sensors measure AC, DC and impulse currents over 0-25, 0-50, 0-100, 0-600 and 0-1200 Amp ranges.
The CSN Series is based on the principles of the Hall effect and the null balance or zero magnetic flux method (feedback system).
The magnetic flux in the sensor core is constantly controlled at zero.
The amount of current required to balance zero flux is the measure of the primary current flowing through the conductor, multiplied by the ratio of the primary to secondary windings.
This closed loop current is the output from the device and presents an image of the primary current reduced by the number of secondary turns a...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)