DatasheetsPDF.com

RGE1200

ETC
Part Number RGE1200
Manufacturer ETC
Description (RGE Series) Selection Guide and Product Data
Published Mar 16, 2007
Detailed Description www.DataSheet4U.com RGE Selection Guide and Product Data This section has two parts: • A Selection Guide that walks you...
Datasheet PDF File RGE1200 PDF File

RGE1200
RGE1200


Overview
www.
DataSheet4U.
com RGE Selection Guide and Product Data This section has two parts: • A Selection Guide that walks you through the process of selecting the correct RGE device for a circuit.
• Product Data that outlines electrical characteristics, physical characteristics, agency recognitions, environmental specifications, component layouts, tape and reel specifications, and ordering information for RGE devices.
RGE Selection Guide Follow these seven steps to select a PolySwitch RGE device for a circuit: 1.
Define the operating parameters for the circuit.
These include: • Maximum ambient operating temperature • Normal operating current • Maximum operating voltage (RGE is 16 V maximum) • Maximum interrupt current 2.
Select the RGE device that accommodates the circuit’s maximum ambient operating temperature and normal operating current.
3.
Compare the RGE device’s maximum operating voltage and maximum interrupt current with the circuit’s to be sure the circuit does not exceed the device ratings.
4.
Check the RGE device’s time-to-trip be to sure it will protect the circuit.
5.
Verify that the circuit’s ambient operating temperatures are within the RGE device’s operating temperature range.
6.
Verify that the RGE device’s dimensions fit the application’s space considerations.
7.
Independently evaluate and test the suitability and performance of the RGE device in the application.
4 ® ® TUV Rheinland Raychem Circuit Protection Devices RGE Devices 129 RGE Radial Leaded 1.
Define the circuit’s operating parameters.
Fill in the following information about the circuit: Maximum ambient operating temperature Normal operating current Maximum operating voltage (RGE is 16 V max.
) Maximum interrupt current ______________ ______________ ______________ ______________ 2.
Select the PolySwitch RGE device that will accommodate the circuit’s maximum ambient operating temperature and normal operating current.
Look across the top of the table below to find the temperature that ...