DatasheetsPDF.com

CT0.2-P

LEM
Part Number CT0.2-P
Manufacturer LEM
Description (CT0.1-P - CT0.4-P) Current Transducers
Published May 31, 2007
Detailed Description Current Transducers CT 0.1 .. 0.4-P For the electronic measurement of small currents: AC,DC, mixed, with a galvanic isol...
Datasheet PDF File CT0.2-P PDF File

CT0.2-P
CT0.2-P


Overview
Current Transducers CT 0.
1 .
.
0.
4-P For the electronic measurement of small currents: AC,DC, mixed, with a galvanic isolation between the primary circuit and the secondary circuit.
IPN = ± 100.
.
400 mA VOUT = ± 5 V Electrical data Primary nominal current rms IPN (mA) 100 200 400 Primary current, measuring range IPM (mA) ± 180 ± 360 ± 720 Type RoHS since date code 46129 46054 46234 Features • DC & AC earth leakage current transducer using a flux-gate principle • PCB mounting • ±15V power supply • ±5V output @ IPN • Insulated plastic case recognized according to UL94-V0.
CT 0.
1-P CT 0.
2-P CT 0.
4-P VC IC RIS VOUT ROUT RL CL Supply voltage (± 5 %) Current consumption Isolation resistance @ ...