HAIS50-P

LEM
Part Number HAIS50-P
Manufacturer LEM
Description Current Transducer
Published Jun 2, 2007
Detailed Description Current Transducer HAIS 50 .. 400-P HAIS 50 .. 150-TP For the electronic measurement of currents: DC, AC, pulsed..., wi...
Datasheet PDF File HAIS50-P PDF File

HAIS50-P
HAIS50-P


Overview
Current Transducer HAIS 50 .
.
400-P HAIS 50 .
.
150-TP For the electronic measurement of currents: DC, AC, pulsed.
.
.
, with galvanic separation between the primary circuit and the secondary circuit.
IPN = 50 .
.
400 A IPN = 50 .
.
150 A Electrical data All data are given with RL = 10 kΩ Primary nominal Primary current Type rms current IPN (A) measuring range IPM (A) 50 ±150 HAIS 50-P/50-TP 1) Features 100 ±300 HAIS 100-P/100-TP 1) 150 ±450 HAIS 150-P/150-TP 1) 200 ±600 HAIS 200-P 400 ±600 HAIS 400-P GTh Theorical sensitivity @ IPN Vout Analog output voltage @ IP Vref Reference voltage 2) Output voltage Output impedance 0.
625 V/ IPN VOE +(0.
625·IP/ IPN) V 2.
5 ±0.
025 V typ.
200 Ω Load impedance ≥200 kΩ RL Load resistance Rout Output internal resistance CL Capacitive loading (±20 %) UC Supply voltage (±5 %) 3) IC Current consumption @ UC = 5 V ≥2 kΩ <5 Ω 4.
7 nF 5 V <19 mA ●● Hall effect measuring principle...