DatasheetsPDF.com

LTC1000-S

LEM
Part Number LTC1000-S
Manufacturer LEM
Description Current Transducer
Published Jun 4, 2007
Detailed Description Current Transducer LTC 1000-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation ...
Datasheet PDF File LTC1000-S PDF File

LTC1000-S
LTC1000-S


Overview
Current Transducer LTC 1000-S For the electronic measurement of currents : DC, AC, pulsed.
.
.
, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 1000 A Electrical data IPN IP ÎP RM Primary nominal r.
m.
s.
current Primary current, measuring range @ ± 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC www.
DataSheet4U.
com 1000 A 0 .
.
± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω Features • Closed loop (compensated) current transducer using the Hall effect @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max • Insulated plastic case recognized according to UL 94-V0 • Railway equipment.
Secondary nominal r.
m.
s.
current Conversion ratio Supply voltage (± 5 %) Current consumption 200 mA 1 : 5000 ± 15 .
.
24 V < 30 (@±24V)+ IS mA Advantages • • • • • • • Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
Accuracy - Dynamic performance data XG Overall accuracy @ IPN , TA = 25°C @ IPN , TA = - 40°C .
.
+ 85°C Linearity error Offset current @ IP = 0, TA = 25°C Thermal drift of IO - 40°C .
.
+ 85°C Response time 2) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) < ± 0.
4 <±1 < 0.
1 Max ± 0.
5 ±1 <1 > 100 DC .
.
100 % % % mA mA µs A/µs kHz ε L IO IOT tr di/dt f Applications • AC variable speed drives and servo motor drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) General data TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 85°C Mass Standards - 40 .
.
+ 85 °C - 45 .
.
+ 90 °C 44 Ω 750 g EN 50155 : 2001 • Switched Mode Power Supplies (SMPS) • Power supplies for welding applications.
Application Domain • Traction Notes : 1) 2) With a di/dt of ...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)