Description Low Noise Amplifier
Published Jul 23, 2007
Detailed Description RoHS Compliant Low Noise Amplifier 0.5 - 3.0 GHz Features • • • • • • • Low Noise Figure: 0.7 dB at 2.3 GHz Single +3 to...
Datasheet PDF File MAAL-007304 PDF File

MAAL-007304
MAAL-007304


Overview
RoHS Compliant Low Noise Amplifier 0.
5 - 3.
0 GHz Features • • • • • • • Low Noise Figure: 0.
7 dB at 2.
3 GHz Single +3 to +5 V Supply Voltage Low Current, 10 mA typical Lead-Free SOT26-6LD 100% Matte Tin Plating over Copper Halogen-Free “Green” Mold Compound RoHS* Compliant and 260°C Reflow Compatible MAAL-007304 V1 Functional Schematic Description M/A-COM’s MAAL-007304 low noise amplifier is a GaAs MMIC amplifier in a lead-free SOT-26 surface mount plastic package.
The MAAL-007304 employs a monolithic 2-stage self-biased design and typically runs from a single 3.
0 volt supply.
Any voltage between 3.
0 and 5.
0 volts can be used, depending on system requirements.
The MAAL-007304 offers low noise, low current, and high gain.
It can be tuned for various applications from 0.
5 to 3 GHz.
M/A-COM fabricates the MAAL-007304 using a low noise PHEMT process to realize low noise and www.
DataSheet4U.
com high gain.
The process features full passivation for performance and reliability.
Pin Configuration Pin No.
1 2 3 4 5 Pin Name VDD1 GND RFIN SRC GND RFOUT Description First stage positive supply voltage RF and DC Ground RF Input of the amplifier First stage source RF and DC Ground RF Output of the amplifier Ordering Information 1 Part Number MAAL-007304-000000 MAAL-007304-TR3000 MAAL-007304-000SMB MAAL-007304-001SMB 6 Package Bulk Packaging 3000 piece reel Sample Board Assy Application use only 2.
3 - 2.
5 GHz Configuration Absolute Maximum Ratings 2,3 Parameter RF Input Power Voltage Operating Temperature Storage Temperature Absolute Maximum -15 dBm 6.
0 volts -40 °C to +85 °C -65 °C to +150 °C 1.
Reference Application Note M513 for reel size information.
2.
Exceeding any one or combination of these limits may cause permanent damage to this device.
3.
M/A-COM does not recommend sustained operation near these survivability limits.