Description Termination-Insensitive Mixer
Published Jul 27, 2007
Detailed Description www.DataSheet4U.com Termination-Insensitive Mixer, 0.5 - 9 GHz Features • Intermodulation Ratio Insensitive to IF Ports...
Datasheet PDF File MDC-164 PDF File

MDC-164
MDC-164



Overview
www.
DataSheet4U.
com Termination-Insensitive Mixer, 0.
5 - 9 GHz Features • Intermodulation Ratio Insensitive to IF Ports Mismatches • Conversion Loss: 6.
5 dB Typical Midband • Maximum Input Power: 350 mW max.
@ 25°C, Derated 3.
5 mW/°C • Low Power: +24 dBm Max.
• MIL-STD-883 Screening Available MDC-164 V3 C-3 Description The unique design of the termination insensitive mixer (TIM) enables it to apply high reverse voltage to diodes during their “off” phase, in the LO cycle.
This allows for higher power level performance with minimum distortion.
In addition the TIM has internal loads that provide a good match and also absorb mixer generated LO frequency terms.
Combined, these features give the mixer its insensitivity to external mismatches, plus superior VSWR.
1 M/A-COM Inc.
and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
• North America Tel: 800.
366.
2266 / Fax: 978.
366.
2266 • Europe Tel: 44.
1908.
574.
200 / Fax: 44.
1908.
574.
300 • Asia/Pacific Tel: 81.
44.
844.
8296 / Fax: 81.
44.
844.
8298 Visit www.
macom.
com for additional data sheets and product information.
Termination-Insensitive Mixer, 0.
5 - 9 GHz Electrical Specifications1: TA = -55°C to +85°C Parameter Frequency Range Conversion Loss2 Test Conditions RF, LO Ports IF Port Frequency 0.
5 - 9 10 - 2000 1 - 7 GHz 0.
5 - 1 GHz 7 - 9 GHz LO to RF 1.
5 - 7 GHz 0.
5 - 9 GHz 1.
5 - 7 GHz 0.
5 - 9 GHz Units GHz MHz dB dB dB dB dB dB dB Min — — — — — 17 13 20 17 Typ — — — — — — — — — MDC-164 V3 Max — — 8.
5 10.
0 11.
0 — — — — Isolation LO to IF RF to IF 0.
5 - 9 GHz dB 17 — — RF Input SSB Noise Figure 3rd Order Input Intercept 1 dB Compression 1 dB Desensitization Within 1 dB of Conversion Loss Max.
— — — 2.
0 ...