Detailed Description GP2Y0A02YK www.DataSheet4U.com GP2Y0A02YK I Features 1. Less influence on the colors of reflected objects and their re...
Datasheet PDF File GP2Y0A02YK PDF File

GP2Y0A02YK
GP2Y0A02YK


Overview
GP2Y0A02YK www.
DataSheet4U.
com GP2Y0A02YK I Features 1.
Less influence on the colors of reflected objects and their reflectivity, due to optical triangle measuring method 2.
Distance output type (Detection range:20 to 150cm) 3.
An external control circuit is not necessary Output can be connected directly to a microcomputer Long Distance Measuring Sensor I Outline Dimensions 4-R1.
75 # # (Unit : mm) 4-R1.
75 Light detector side R3.
75 13 11.
9 +0.
5 18.
9− 0.
3 37 29.
5 4.
475 19.
8 ±0.
1 Lens case R3.
75 φ3.
2 Light emitter side φ3.
2 10.
1 4.
5 8.
95 10.
45 14.
4 I Applications 1.
For detection of human body and various types of objects in home appliances, OA equipment, etc Connector PWB 3.
3 1.
2 14.
4 I Absolute Maximum Ratings Parameter Supply voltage *1 Output terminal voltage Operating temperature Storage temperature *1 Open collector output (Ta=25°C) Symbol Rating Unit V −0.
3 to +7 VCC VO −0.
3 to VCC +0.
3 V −10 to +60 Topr °C Tstg −40 to +70 °C 1 3 ❈ The dimensions marked # are described the dimensions of lens center position.
❈ Unspecified tolerance : ±0.
3mm 2-1.
5 21.
6 Terminal connection 1 2 3 VO GND VCC I Recommended Operating Conditions Parameter Operating Supply voltage Symbol VCC Rating 4.
5 to 5.
5 Unit V Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.
com/ecg/ GP2Y0A02YK I Electro-optical Characteristics Parameter Symbol Conditions *2 *3 MIN.
20 Distance measuring range Output terminal voltage Difference of output voltage Average dissipation current ∆L VO ∆VO ICC L=150cm *2 Output change at L=150cm to 20cm − *2 0.
25 1.
8 − (Ta=25°C, VCC=5V) TYP.
MAX.
Unit 150 cm − V 0.
4 0.
55 2.
05 V 2.
3 33 50 mA Note) L:Distance to ref...