Detailed Description STTH10R04 www.datasheet4u.com High efficiency rectifier Features A K ■ ■ ■ ■ ■ Ultrafast recovery Low power losses H...
Datasheet PDF File STTH10R04 PDF File

STTH10R04
STTH10R04


Overview
STTH10R04 www.
datasheet4u.
com High efficiency rectifier Features A K ■ ■ ■ ■ ■ Ultrafast recovery Low power losses High surge capability Low leakage current High junction temperature K A NC A K TO-220FPAC STTH10R04FP K D2PAK STTH10R04G Description The STTH10R04 is an ultrafast recovery power rectifier dedicated to energy recovery in PDP application.
It is especially designed for clamping function in energy recovery block.
The compromise between forward voltage drop and recovery time offers optimized performances.
K A A K NC TO-220AC STTH10R04D DPAK STTH10R04B Table 1.
Device summary IF(peak) VRRM trr (typ) Tj VF (typ) 10 A 400 V 15 ns 175 °C 1.
15 V November 2007 Rev 1 1/11 www.
st.
com 11 Characteristics STTH10R04 1 www.
datasheet4u.
com Characteristics Absolute ratings (limiting values) Parameter Repetitive peak reverse voltage Forward current (rms) DPAK, TO-220AC, D2PAK IF(peak) Peak working forward current TO-220FPAC IFSM Tstg Tj Surge non-repetitive forward current Storage temperature range Maximum operating junction temperature Tc = 135 °C δ = 0.
5 Square signal Tc = 130 °C δ = 0.
5 Square signal tp = 10 ms sinusoidal 10 A Value 400 20 Unit V A Table 2.
Symbol VRRM IF(RMS) 100 -65 to + 175 175 A °C °C Table 3.
Symbol Rth(j-c) Thermal parameters Parameter DPAK, TO-220AC, D2PAK Junction to case TO-220FPAC 6 Value 3.
5 °C/W Unit Table 4.
Symbol IR (1) VF (2) Static electrical characteristics Parameter Reverse leakage current Test conditions Tj = 25 °C Tj = 125 °C Forward voltage drop Tj = 25 °C Tj = 125 °C VR = VRRM Min Typ Max 10 µA 10 1.
5 IF = 10 A 1.
15 100 1.
7 V 1.
35 Unit 1.
Pulse test: tp = 5 ms, δ < 2% 2.
Pulse test: tp = 380 µs, δ < 2% To evaluate the conduction losses use the following equation: P = 1.
05 x IF(AV) + 0.
03 IF2(RMS) Table 5.
Symbol trr tfr VFP IRM Sfactor Recovery characteristics Parameter Reverse recovery time Tj = 25 °C Tj = 25 °C Tj = 25 °C Test conditions IF = 0.
5 A, Irr = 0.
25 A, IR = 1 A IF = 1 A, VR = 30 V, dIF/dt ...