DatasheetsPDF.com

STTH20LCD06C

ST Microelectronics
Part Number STTH20LCD06C
Manufacturer ST Microelectronics
Description Ultrafast Rectifier
Published Aug 7, 2009
Detailed Description STTH20LCD06C Turbo2 ultrafast - high voltage rectifier for SMPS Features ■ ultrafast switching ■ low reverse current ■ ...
Datasheet PDF File STTH20LCD06C PDF File

STTH20LCD06C
STTH20LCD06C


Overview
STTH20LCD06C Turbo2 ultrafast - high voltage rectifier for SMPS Features ■ ultrafast switching ■ low reverse current ■ low thermal resistance ■ reduces conduction and switching losses Description The STTH20LCD06C uses ST Turbo2 technology.
This device is specially suited for switching power supplies working with interleaved PFCs.
A1 K A2 A2 K A1 TO-220AB STTH20LCD06CT A2 K A1 TO-220FPAB STTH20LCD06CFP K A2 A1 D2PAK STTH20LCD06CG-TR Table 1.
Device summary IF(AV) VRRM Tj VF (typ) trr (max) 2 x 10 A 600 V 175 °C 1.
25 V 50 ns January 2011 Doc ID 15898 Rev 2 1/10 www.
st.
com 10 Characteristics 1 Characteristics STTH20LCD06C Table 2.
Absolute ratings(1) Symbol Parameter Value VRRM Repetitive peak reverse voltage 600 IF(RMS) Forward current rms 30 IF(AV) Average forward current, δ = 0.
5 Tc = 105 °C TO-220AB, D2PAK Per diode Per device Per diode 10 20 10 Tc = 60 °C TO-220FPAB Per device 20 IFSM Surge non repetitive forward current tp = 10 ms sinusoidal 80 Tstg Storage temperature range Tj Maximum operating junction temperature(2) -65 to + 175 175 1.
Limiting values per diode at 25 °C, unless otherwise specified 2.
dPtot dTj <1 Rth(j-a) condition to avoid thermal runaway for a diode on its own heatsink Table 3.
Thermal resistance Symbol Parameter Value Rth(j-c) Junction to case TO-220AB, D2PAK 3.
5 TO-220FPAB 5.
8 Unit V A A A A A A °C °C Unit °C/W Table 4.
Static electrical characteristics Symbol Parameter Test conditions Min.
Typ.
Max.
Unit IR(1) Reverse leakage current Tj = 25 °C - Tj = 150 °C VR = VRRM - Tj = 25 °C - IF = 10 A VF(2) Forward voltage drop Tj = 150 °C - Tj = 25 °C - IF = 20 A Tj = 150 °C - 1.
Pulse test: tp = 5 ms, δ < 2 % 2.
Pulse test: tp = 380 µs, δ < 2 % To evaluate the conduction losses use the following equation: P = 1.
2 x IF(AV) + 0.
04 x IF2(RMS) - 1 µA 10 100 - 2 1.
25 1.
6 V - 2.
35 1.
55 2 2/10 Doc ID 15898 Rev 2 STTH20LCD06C Characteristics Table 5.
Symbol Dy...