DatasheetsPDF.com

CXA10-48D12Y

Emerson
Part Number CXA10-48D12Y
Manufacturer Emerson
Description DC-DC / Low Power Isolated Industrial
Published Oct 25, 2009
Detailed Description Embedded Power for Business-Critical Continuity CXA10 Single output Rev.12.04.07 cxa10 1 of 4 Total Power: 10W Input ...
Datasheet PDF File CXA10-48D12Y PDF File

CXA10-48D12Y
CXA10-48D12Y


Overview
Embedded Power for Business-Critical Continuity CXA10 Single output Rev.
12.
04.
07 cxa10 1 of 4 Total Power: 10W Input Voltage: 18 - 75VDC # of Outputs: Single Special Features • 4:1 input voltage range • Operating ambient temperature of -40°C to +70°C in still air • High demonstrated reliability with conservative component deratings • Complies with ETS 300 019-1-3/2-3 • Complies with ETS 300 132-2 input voltage and current requirements • Fully compliant with ETS 300 386-1 • Pin compatible with NFC10 and BXA10 series • Basic insulation system (input to output) • 2 year warranty The CXA10 series comprising of five different models delivers single and dual output voltages covering 3.
3 V, 5 V, 12 V, ±5 V, ±12 V and ±15 V.
The series has a wide 4:1 input voltage range of 18Vdc to 75 Vdc.
The CXA10 has been designed as a competitive open-frame alternative for the communications market.
The product is supplied in the industry standard footprint of 2.
0 x 1.
0 x 0.
394 inches.
Other product features include overvoltage protection, short-circuit protection and remote ON/OFF.
All components are placed in a fully automated environment.
Planar magnetics are used in the design to improve the reliability and reduce the profile of the dc-dc converter.
The series has full international safety approvals reducing system compliance costs, and it has a basic insulation system from input to output making it suitable for a wide variety of applications.
Safety UL/cUL CAN/CSA 22.
2 No.
60950-00 : UL 60950-1 File No.
E132002 VDE Certificate No.
112607.
File No.
1040100-3336-0136 CB Report and Certificate to IEC60950-1, #DE 1-30686 Embedded Power for Business-Critical Continuity Specifications All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Rev.
12.
04.
07 cxa10 2 of 4 OUTPUT SPECIFICATIONS Voltage accuracy Line regulation (LL to HL) Load regulation (not incl.
cross reg.
) Min.
load Ripple and noise 20 MHz bandwidth Temperature coefficient Overvolt...