DatasheetsPDF.com

EXB100-48S3V3-RJ

Emerson
Part Number EXB100-48S3V3-RJ
Manufacturer Emerson
Description DC-DC / Industry Standard Isolated Half Brick
Published Oct 25, 2009
Detailed Description EXB100 Series DC-DC CONVERTERS • • • • • • • • Single output 100 W DC-DC Isolated Converters NEW Product 1 Ultra wide...
Datasheet PDF File EXB100-48S3V3-RJ PDF File

EXB100-48S3V3-RJ
EXB100-48S3V3-RJ


Overview
EXB100 Series DC-DC CONVERTERS • • • • • • • • Single output 100 W DC-DC Isolated Converters NEW Product 1 Ultra wide trim range, 60% to 110% (1.
08 Vdc to 5.
5 Vdc) High efficiency, 91.
5% @ 5 Vdc, 90.
5% @ 3.
3 Vdc Basic insulation (input to output) Industry standard half-brick pin-out No minimum load Overvoltage and overtemperature protection Remote ON/OFF Available RoHS compliant The EXB100 series of 100 W single output isolated dc-dc converters are specially designed to meet the power needs of low voltage silicon.
Housed in an open-frame package with standard footprint, these latest generation converters offer efficiencies as high as 91.
5% (typical on 5 V at 20 A).
The series comprises two 48 V input models with 5 V and 3.
3 V outputs.
The 3.
3 V model features a wide input range, trimmable output voltage and 30 A output (the 5 V model is limited to 20 A).
Remote sense and remote ON/OFF facilities are included as standard, and the converters are comprehensively protected against overcurrent, overvoltage and overtemperature conditions.
2 YEAR WARRANTY All specifications are typical at nominal input, full load at 25 °C unless otherwise stated SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage adjustability Output setpoint accuracy Line regulation Load regulation Total error band Minimum load Overshoot Undershoot Ripple and noise 5 Hz to 20 MHz Transient response (See Note 2) (See Note 1) Deviation At turn-on and turn-off Low line to high line Full load to min.
load 60% to 110% 1.
5% ±0.
2% max.
±0.
4% max.
3.
0% 0% None None 100 mV pk-pk 50 mV rms 150 mV 300 µs recovery to within total error band EMC CHARACTERISTICS Conducted emissions Radiated emissions Immunity: ESD air ESD contact Radiated field enclosure Conducted (DC power) Conducted (signal) Input transients EN55022 (See Note 7) EN55022 (See Note 7) EN55022 (See Longform Datasheet) Level A Level B Level A EN61000-4-2 8 kV, 15 kV EN61000-4-2 6 kV, 8 kV EN61000-4-3 10 V/m EN61000-4-6 10 V EN61000-4-6 10 V (See Note 5)...