DatasheetsPDF.com

LPQ113-B

Emerson
Part Number LPQ113-B
Manufacturer Emerson
Description AC-DC / 86W - 135W
Published Oct 25, 2009
Detailed Description 110 Watts LPQ110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad Electrical...
Datasheet PDF File LPQ113-B PDF File

LPQ113-B
LPQ113-B


Overview
110 Watts LPQ110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad Electrical Specs Input Input range Frequency Inrush current Input current Efficiency EMI filter 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.
5 A max.
(RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.
5 mA @ 50/60 Hz, 264 VAC input Special Features • • • • • • • • • Universal input High efficiency Remote sense on main output Built-in EMI filter Low output ripple Adjustable 5 V output Overvoltage protection Overload protection Adjustable floating 4th output (On LPQ112 and LPQ113) • Power fail • Optional L bracket (-B suffix) • Cover kit available LPX110-C Safety ground leakage current Output Maximum power Adjustment range Cross regulation Hold-up time Overload protection Overvoltage protection 80 W for convection; 110 W with 30 CFM forced air ±5% min.
on main; 5-25 V on 4th output on LPQ112 and LPQ113 ±2% on output 1; ±3% on outputs 2, 3 & 4 20 ms @ 80 W load, 115 VAC nominal line Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating 5.
7-6.
7 VDC on main output.
Latching type, recycle AC to reset.
Environmental Operating temperature: 0° to 50°C ambient derate each output at 2.
5% per degree from 50° to 70°C Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min.
dwell at four major resonances 0.
75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.
04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Logic Control Power Failure Remote sense TTL logic signal goes high 50-150 msec after 5 V output.
It goes low at least 4 msec before loss of regulation.
Compensa...



Similar Datasheet