DatasheetsPDF.com

LPT45-M

Emerson
Part Number LPT45-M
Manufacturer Emerson
Description AC-DC / 10W - 85W Medical
Published Oct 25, 2009
Detailed Description Embedded Power for Business-Critical Continuity LPT40-M Series 40 Watts Total Power: Input Voltage: # of Outputs:...
Datasheet PDF File LPT45-M PDF File

LPT45-M
LPT45-M


Overview
Embedded Power for Business-Critical Continuity LPT40-M Series 40 Watts Total Power: Input Voltage: # of Outputs: 40 - 55 Watts 85 - 264 VAC 120 - 300VDC Triple Rev.
6.
30.
09_165 LPT40-M Series  of 3 Special Features • • • • • • • • • • • Universal input 3” x 5” footprint Less than 1U high Remote sense on main output Built-in EMI filter Low output ripple Adjustable 5V output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Electrical Specifications Input Input ra­nge: Frequency: Inrush current: Input current: Efficiency: EMI:  5 - 264 VAC 8 120 - 300 VDC 47 - 440 Hz < 18A peak @ 115 VAC;  < 36A peak @ 230 VAC, cold start @ 25 °C 1A max.
(RMS) @ 115VAC 70% typical at full load (60% for LPT41) FCC Class A conducted; CISPR 22 Class A conducted  EN55022 Class A conducted; VDE 0878 PT3 Class A conducted < 75 µA @ 50/60 Hz, 264 VAC input Safety ground leakage current: Output Maximum Power: 40W for convection; 55W with 30CFM forced air ± 2% on output 1; ± 5% on outputs 2, 3 -5, +10% minimum 20ms @ 40W load, 115 VAC nominal line Short circuit protection on all outputs.
Case overload protected  @ 110% to 145% above peak rating 5.
7 to 6.
7 VDC on the main output LPT41: 3.
6 to 4.
6VDC Compensates for 0.
5 V lead drop min.
Will operate without remote sense connected.
Reverse connection protected.
Cross regulation: Adjustment range: Hold-up time: Overload protection: Overvoltage protection: Remote sense: Safety • • • • VDE UL CSA CE 0750/EN60601-1 (IEC601) 113769 UL2601 E182560 CSA 22.
2 No.
601.
1 LR109492 Mark (LVD) Embedded Power for Business-Critical Continuity Rev.
6.
30.
09_165 LPT40-M Series  of 3 Environmental Specifications Operating temperature: Electromagnetic susceptibility: Humidity: Vibration: Storage temperature: Temperature coefficient: MTBF demonstrated: 0° to 50 °C ambient derate each output at 2.
5% per degree from 50° to 70 °C, -20 °C start up.
Designed to meet IEC 801, ...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)