DatasheetsPDF.com

NFS40-7928J

Emerson
Part Number NFS40-7928J
Manufacturer Emerson
Description AC-DC / 10W - 85 W Medical
Published Oct 25, 2009
Detailed Description Embedded Power for Business-Critical Continuity NFS40 Medical Series Single & Triple Output Total Power: Input Voltage...
Datasheet PDF File NFS40-7928J PDF File

NFS40-7928J
NFS40-7928J


Overview
Embedded Power for Business-Critical Continuity NFS40 Medical Series Single & Triple Output Total Power: Input Voltage: # of Outputs: 40 - 50W 85 - 264 VAC 120 - 370 VDC Single, triple Rev.
06.
9.
09_118 NFS40 Medical  of 4 Special Features • 5.
0 x 3.
0 x 1.
2 inch package (1U applications) • Industry standard package • Overvoltage and short circuit protection • 40 W with free air convection • EN55022, EN55011 conducted noise level A • UL, VDE and CSA safety approvals • Available RoHS compliant • 2 year warranty Electrical Specifications Output Voltage adjustability: Line regulation: LL to HL, FL Load regulation: FL to NL Transient response: Temperature coefficient: Overvoltage protection: Output power limit: Short circuit protection: +5 V output on triples Vout on singles Main output Auxiliary outputs Main output Auxiliary outputs +5 V (1.
5 - 3 A step) All outputs +5 V output Primary power limited Single outputs Multiple outputs ± 5.
0% ± 5.
0% ± 0.
2% ± 1.
0% ± 2.
0% ± 5.
0% ± 120 mV max.
dev.
500 µs recovery ±0.
02%/°C 6.
25 ± 0.
75 Vout 90 W input power limit Continuous Short term 85 - 264 Vac 120 - 370 Vdc 47 - 440 Hz 110 Vac, 60 Hz, cold start 230 Vac, 50 Hz, cold start 110 Vac, 60 Hz 230 Vac, 50 Hz 10 A 22 A 18 µA max.
28 µA max.
Input Input voltage range: Safety • UL2601 • CSA22.
2 No.
125 • IEC601/VDE0750 Input frequency range: Input surge current: Safety ground leakage current: Embedded Power for Business-Critical Continuity Rev.
06.
9.
09_118 NFS40 Medical  of 4 Electrical Specifications Continued All specifications are typical at nominal input, full load at 25 °C unless otherwise stated EMC Charateristics Conducted emissions: Radiated emissions: ESD air: ESD contact: Surge: Fast transients: Radiated immunity: Conducted immunity: EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 110 Vac 230 Vac 110 Vac, 230 Vac Input/output Input/chassis ...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)