H HiTRON AUTO-RANGING INPUT AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES HIH100 & HVI100 SERIES FEATURES: AUTO-RANGING ACCOMMODATE AC SOURCES BOX OR L-BRACKET FORMAT MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB.
22 & FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION Input Voltage: Auto-ranging 115(90-132) Vac and 230(180-264) VAC.
Transient threshold 150Vac typical.
(Option for dual input selectable) Input Connector: See Pin assignment.
Input Frequency: 47-63Hz.
Inrush Current: Typ.
20A@115Vac, 40A@230Vac.
Input Current: 2.
5A @115Vac, 1.
1A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB.
22 & FCC Class B.
www.
DataSheet4U.
com Hold-up Time: Typ.
22mS @115Vac, 27mS @230Vac.
Earth leakage: Typ.
0.
5mA @230Vac.
Power Fail Signal: Installed.
Logic Inhibit: Optional in HIH100-1X and HVI100-2X dual output series.
OUTPUT SPECIFICATION Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ.
100 watts.
Output Connector: See pin assignment.
Line Regulation: Typ.
0.
1%.
Load Regulation: Main VO1 typ.
±1.
0%.
Aux.
VO2 typ.
±2.
0%.
(Magnetic Amp.
) Aux.
VO2 typ.
±5.
0%.
(Stacked-on.
) Aux.
VO3/VO4 typ.
±1.
5%.
(P.
R.
) Noise & Ripple: Typ.
1.
0% peak to peak.
OVP: Built-in at main VO1.
Adjustability: Available at VO1 & VO2.
Remote Sense: Optional in HIH100 & HVI100-2X.
Overload Protection (OLP): Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION Efficiency: Typ.
75%.
Switching Frequency: Fixed-frequency at 100K Hz.
Circuit Topology: Fixed-frequency forward circuit.
Transient Response: Output voltage returns in less than 3ms following a 25% load change.
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Power Density: 1.
56Watts / Cubic Inch.
Operating Temperature: 0 to +50°C under forced air flow for full load.
Storage Temperature: -20 to +85°C.
Temperature Coef...