MITSUBISHI SEMICONDUCTOR
PS21961-T/-AT/-CT/-TW
TRANSFER-MOLD TYPE INSULATED TYPE
PS21961-T
INTEGRATED POWER FUNCTIONS
600V/3A low-loss RC-IGBT inverter bridge for three phase DC-to-AC power conversion
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS
• • • • • For upper-leg IGBTS : Drive circuit, High voltage high-speed level shifting, Control supply under-voltage (UV) protection. For lower-leg IGBTS : Drive circuit, Control supply under-voltage protection (UV), Short circuit protection (SC), Over temperature protection (OT). Fault signaling : Corresponding to an SC fault (Lower-leg IGBT), a UV fault (Lower-side supply) or an OT fault (LVIC temperature). Input interface : 3V, 5V line (High Active). UL Approved : Yellow Card No. E80276
APPLICATION AC100V~200V three phase low power motor inverter drive.
Fig. 1 PACKAGE OUTLINES (PS21961-T)
38 ±0. 5 20×1. 778(=35. 56) 35 ±0. 3 A
www. DataSheet. net/
Dimensions in mm B TERMINAL CODE 3. ...