DatasheetsPDF.com

HXS50-NP

LEM
Part Number HXS50-NP
Manufacturer LEM
Description Current Transducer
Published Apr 30, 2013
Detailed Description Current Transducer HXS 50-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolati...
Datasheet PDF File HXS50-NP PDF File

HXS50-NP
HXS50-NP


Overview
Current Transducer HXS 50-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 12.
5 - 25 - 50 A All Data are given with a R L = 10 k Ω Electrical data IPN IP VOUT VREF Primary nominal r.
m.
s.
current Primary current measuring range Analog output voltage @ IP IP = 0 Internal Reference 1) - Output voltage VREF Output impedance VREF Load impedance Output load resistance Output impedance Max.
output capacitive load Supply voltage (± 5 %) Current consumption @ VC = 5 V ± 50 A ± 150 A VREF ± (0.
625·IP/IPN) V VREF ± 0.
0125 V 2.
5 ± 0.
025 V typ.
200 Ω ≥ 200 kΩ ≥2 kΩ < 10 Ω <1 µF 5 V 22 mA Features • Hall effect measuring principle • Multirange current transducer through PCB pattern lay-out • Galvanic isolation between primary • Isolation test voltage 3500V • Low power consumption • Extremely low profile, < 11mm • Single power supply +5V • Fixed offset & ...