Published Jun 11, 2013
Detailed Description SYH-2R (Industrial Version) HUMIDITY SENSOR TO : HUMIDITY SENSOR P/N : SYH-2R__.I [ INDUSTRIAL VERSION ] =============...
Datasheet PDF File SYH-2R PDF File

SYH-2R
SYH-2R


Overview
SYH-2R (Industrial Version) HUMIDITY SENSOR TO : HUMIDITY SENSOR P/N : SYH-2R__.
I [ INDUSTRIAL VERSION ] ======================================== SPECIFICATIONS http://www.
DataSheet4U.
net/ ======================================== SAMYOUNG S&C Co.
, LTD.
datasheet pdf - http://www.
DataSheet4U.
net/ SYH-2R (Industrial Version) HUMIDITY SENSOR 1.
Scope of application This specification is applicable to the resistive type humidity sensor SYH-2R (Industrial Version) 2.
Type SY H 2 R .
I .
I : Industrial C : With case NC : Without case R : Resistor electrode 2 : 33kΩ spec.
(25℃, 60%RH) H : Resistive Humidity Sensor SY : SAMYOUNG S&C 2-1.
SYH-2RC.
I : 2-2.
SYH-2RNC.
I : Humidity sensor unit with Case Humidity sensor unit (No Case) 3.
Configuration The configuration of the humidity sensor unit is shown on the Fig.
1.
http://www.
DataSheet4U.
net/ 4.
Electrical characteristics 4-1.
Rated voltage 4-2.
Rated power 4-3.
Standard characteristic 4-4.
Operating temperature 4-5.
Operating humidity range 4-6.
Operating frequency range 4-7.
Storage temperature range 4-8.
Storage humidity range 4-9.
Accuracy 4-10.
Hysteresis 4-11.
Response time 4-12.
Temperature coefficient : MAX.
AC 5Vpp (recommended 1VRMS) : 0.
26mW (at 1VRMS) : 33㏀ (at 25°C, 60%RH, 1VRMS, 1kHz) : -20°C ∼ 85°C : 10 ∼ 95%RH (non-condensing) : 100Hz ~ 10kHz : -30°C ∼ 85°C : Less than 95%RH (non-condensing) : ±3%RH (at 25°C, 60%RH) : Within 2%RH (at 25°C, 40⇔80%RH) : < 45 sec.
(30⇔90%RH), T80) : - 0.
5%RH / °C [Fig.
4] [Fig.
2] [Fig.
3] SAMYOUNG S&C Co.
, LTD.
datasheet pdf - http://www.
DataSheet4U.
net/ SYH-2R (Industrial Version) HUMIDITY SENSOR 5.
Reliability Test No Test Item Test Condition Criterion - Temperature: 85℃ Test time: 1,000 hours 1 High Temperature Storage Recovery time : 1 ~ 2 hours - Temperature:- 30℃ Test time: 1,000 hours.
2 Low Temperature Storage Recovery time : 1 ~ 2 hours - Temperature: 40℃, Humidity : 95 %RH High Temperature/High 3 Humidity Loading Test time : 1000 hours, Bias : 1Vpp, 1kH...