Part Number LW020
Manufacturer Lineage Power
Description Single-Output-Series Power Modules
Published Nov 1, 2013
Detailed Description Data Sheet April 2008 LW020 Single-Output-Series Power Modules: 36 Vdc to 75 Vdc Inputs; 20 W Features n Low profile: ...
Datasheet PDF File LW020 PDF File

LW020
LW020


Overview
Data Sheet April 2008 LW020 Single-Output-Series Power Modules: 36 Vdc to 75 Vdc Inputs; 20 W Features n Low profile: 9.
91 mm (0.
390 in.
) with 0.
38 mm (0.
015 in.
) standoffs, 9.
53 mm (0.
375 in.
) with standoffs recessed Wide input voltage range: 36 Vdc to 75 Vdc Overcurrent protection Output overvoltage protection Input-to-output isolation: 1500 Vdc Operating case temperature range: –40 °C to +110 °C Remote on/off Output voltage adjustment: 90% to 110% of VO, nom JQA Certified to EN60950 UL* 1950 Recognized, CSA† C22.
2 No.
950-95 Certified, VDE‡ 0805 (EN60950, IEC950) Licensed CE mark meets 73/23/EEC and 93/68/EEC directives§ Within FCC Class A radiated limits n n n n n n The LW020 Single-Output-Series Power Modules use advanced, surface-mount technology and deliver high-quality, compact, dc-dc conversion at an economical price.
n n n Applications n n n n Distributed power architectures Communication equipment Computer equipment n Description The LW020 Single-Output-Series Power Modules are low-profile dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide precisely regulated outputs.
The outputs are isolated from the input, allowing versatile polarity configurations and grounding connections.
Built-in filtering for both input and output minimizes the need for external filtering.
The modules have a maximum power rating of 20 W at a typical full-load efficiency of up to 85%.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.
V.
§ This product is intended for integration into end-use equipment.
All the required procedures for CE marking of end-use equipment should be followed.
(The CE mark is placed on selected products.
) Options n n n n Choice of remote on/off configuration Case ground pin Synchronization Short pins: 2.
79 mm ± 0.
25 mm (0.
110 in.
± 0.
010 in.
) Short pins: 3.
68 mm ± 0.
...