DatasheetsPDF.com

SRUUH-SH-112D1

Tyco
Part Number SRUUH-SH-112D1
Manufacturer Tyco
Description 15 Amp Miniature Power PC Board Relay
Published May 29, 2014
Detailed Description Catalog 1308242 Issued 3-03 (PDF Rev. 3-04) OEG SRUUH series 15 Amp Miniature Power PC Board Relay UL File No. E82292 ...
Datasheet PDF File SRUUH-SH-112D1 PDF File

SRUUH-SH-112D1
SRUUH-SH-112D1


Overview
Catalog 1308242 Issued 3-03 (PDF Rev.
3-04) OEG SRUUH series 15 Amp Miniature Power PC Board Relay UL File No.
E82292 TUV File No.
R60271 Users should thoroughly review the technical data before selecting a product part number.
It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application.
Features • 15 Amp switching capacity.
• 1 Form A and 1 Form C contact arrangements.
• Immersion cleanable, sealed version available.
• Applications include appliance, HVAC, security system, garage opener control, emergency lighting.
Coil Data @ 20°C SRUUH Rated Coil Voltage (VDC) 3 6 9 12 24 48 Nominal Current (mA) 120 60 40 30 15 10 Coil Resistance (ohms) ± 10% 25 100 225 400 1,600 4,500 Must Operate Voltage (VDC) 2.
25 4.
50 6.
75 9.
00 18.
00 36.
00 Must Release Voltage (VDC) 0.
30 0.
60 0.
90 1.
20 2.
40 4.
80 Contact Data @ 20°C Arrangements: 1 Form A (SPST-NO) and 1 Form C (SPDT).
Material: Silver cadmium oxide.
Max.
Switching Rate: 300 ops.
/min.
(no load).
20 ops.
/min.
(rated load).
Expected Mechanical Life: 10 million operations (no load).
Expected Electrical Life: 100,000 operations (rated load, relay vented).
Minimum Load: 100mA @ 5VDC.
Initial Contact Resistance: 100 milliohms @ 1A, 6VDC.
Operate Data Must Operate Voltage: 75% of nominal voltage or less.
Must Release Voltage: 10% of nominal voltage or more.
Operate Time: 15 ms max.
Release Time: 5 ms max.
Contact Ratings Ratings: 15A @ 120VAC resistive, 10A @ 240VAC resistive, 10A @ 28VDC resistive.
Max.
Switched Voltage: AC: 240V.
DC: 28V.
Max.
Switched Current: 15A.
Max.
Switched Power: 2,400VA, 300W.
Note: Sealed relays should be vented after soldering and cleaning in order to achieve listed ratings.
Environmental Data Temperature Range: Operating: -30°C to +60°C Vibration, Mechanical: 10 to 55 Hz.
, 1.
5mm double amplitude Operational: 10 to 55 Hz.
, 1.
5mm double amplitude.
Shock, Mechanical: 1,000m/s...