DatasheetsPDF.com

TGS826

Figaro
Part Number TGS826
Manufacturer Figaro
Description Ammonia Detection
Published Oct 20, 2014
Detailed Description FIGARO PRODUCT INFORMATION TGS 826 - for the Detection of Ammonia Features: * High sensitivity to ammonia * Quick resp...
Datasheet PDF File TGS826 PDF File

TGS826
TGS826


Overview
FIGARO PRODUCT INFORMATION TGS 826 - for the Detection of Ammonia Features: * High sensitivity to ammonia * Quick response to low concentrations of ammonia * Uses simple electrical circuit * Ceramic base resistant to severe environment Applications: * Ammonia leak detection in refrigerators * Ventilation control for the agricultural and poultry industries The sensing element of TGS826 is a metal oxide semiconductor which has low conductivity in clean air.
In the presence of a detectable gas, the sensor's conductivity increases depending on the gas concentration in the air.
A simple electrical circuit can convert the change in conductivity to an output signal which corresponds to the gas concentration.
The TGS826 has high sensitivity to ammonia gas.
The sensor can detect concentrations as low as 30ppm in the air and is ideally suited to critical safety-related applications such as the detection of ammonia leaks in refrigeration systems and ammonia detection in the agricultural field.
The figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see reverse side of this sheet).
The Y-axis is indicated as sensor resistance ratio (Rs/Ro) which is defined as follows: Rs = Sensor resistance of displayed gases at various concentrations Ro = Sensor resistance at 50ppm of ammonia Sensitivity Characteristics: 10 Air The figure below represents typical temperature and humidity dependency characteristics.
Again, the Y-axis is indicated as sensor resistance ratio (Rs/Ro), defined as follows: Rs = Sensor resistance at 50ppm of ammonia at various temperatures/humidities Ro = Sensor resistance at 50ppm of ammonia at 20°C and 65% R.
H.
Temperature/Humidity Dependency: 10.
0 Rs/Ro 1 Rs/Ro Iso-butane Hydrogen Ammonia 0% 1.
0 RH% 20% 40% 65% 100% Ethanol 0.
1 10 100 1000 0.
1 -30 -20 -10 0 10 20 30 40 50 Concentration (ppm) Ambient Temperature (°C) IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO S...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)