Part Number PT124B-112DT
Manufacturer ZHYQ
Description Auto-zero Adjustment Melt Pressure Transmitter
Published Feb 16, 2015
Detailed Description Auto-zero Adjustment Melt Pressure Transmitter Model:PT124B-112D/112DT Description PT124B-112D/112DT Series rigid stem ...
Datasheet PDF File PT124B-112DT PDF File

PT124B-112DT
PT124B-112DT


Overview
Auto-zero Adjustment Melt Pressure Transmitter Model:PT124B-112D/112DT Description PT124B-112D/112DT Series rigid stem melt pressure transmitter is designed with auto-zero adjustment function, it can realize the automatic calibration and amendment with one button on the top of the electrical house of the pressure transmitter, in order to reduce the consuming of manpower, cost of calibrating equipment, and save operating time.
The model PT124B-112DT comes with thermocouple, it can be used to measure the pressure and temperature in one point.
The amplifier output is 4-20mA, which can directly contact with PLC.
This series is suitable for pressure measuring and controlling of melt fluid medium, such as the plastic & polymer in the process equipments.
Application ‹ Chemical fiber & spinning Equipment ‹ Plastic and rubber, polyester process equipment ‹ Other pressure measurement and Control Feature ‹ High-standard quality ‹ Auto-Zero functionality ‹ No span or zero pots ‹ Simple Installation ‹ Completely interchange similar import products ‹ Internal 80% calibration ‹ Excellent stability Dimension Φ37.
5 0 -0.
05 SW16 27.
5 5.
50 1/2-20UNF Φ10.
5 Φ7.
8 Φ12.
7 Φ10.
7 11.
5 PT124B-112D 75 0 -0.
05 29 5.
50 Φ41 13.
5 L+113 SW16 45° L 11.
5 Thermocoup l e Φ10.
7 Φ12.
7 Φ7.
8 Φ10.
5 1/2-20UNF 11.
5 45° L=152 PT124B-112DT 13.
5 254 73 ZHYQ Sensor & Control Page 1 of 4 Melt Pressure Transmitter Specification Range: Output: Accuracy: Input voltage: Repeatability: Construction: Load Resistance: Overload pressure: Internal Shunt Calibration (R-cal): Insulation Resistance: Standard wetted parts: Electronic operating temperature: Zero Shift due to temperature change: Sensitivity due to temperature change: Max.
Diaphragm Temp: Thermocouple: Electric connection: Process connection: 0…3.
5MPa to 0….
150MPa 4-20mA ±0.
5%FS; ±0.
25%FS optional 14~36V DC ±0.
2% FSO Four-arm bonded foil wheatstone bridge strain gauge 0-1100 ohms 2×FSO 80% FSO±1% 1000 megohms @ 50Vdc 15-5PH -25℃ -85℃ ...