Detailed Description AC-DC 80-240 Watts DRS80-240 Series xppower.com • Ultra Slim Cases • 150% Peak Load for 4 seconds • Wide Output Adjust...
Datasheet PDF File DRS120PS24 PDF File

DRS120PS24
DRS120PS24


Overview
AC-DC 80-240 Watts DRS80-240 Series xppower.
com • Ultra Slim Cases • 150% Peak Load for 4 seconds • Wide Output Adjustment Range • High Efficiency – Up to 92% • 12 V, 24 V & 48 V Versions • Low Output Ripple & Noise • -20 ºC to 70 ºC Operating Temperature Specification Input Input Voltage • 85-264 VAC Input Frequency • 47-63 Hz Input Current • 80 W: 2 A at 85 VAC 120 W: 2 A at 85 VAC 240 W: 4 A at 85 VAC Inrush Current • 30 A max at 230 VAC Power Factor • DRS80 0.
6 typical DRS120 & 240 0.
95 typical Conforms to EN61000-3-2 Class A.
Earth Leakage Current • 1.
5 mA maximum Output Output Voltage • See table Output Voltage Trim • See table Initial Set Accuracy • ±1% at 50% load Minimum Load • No minimum load required Start Up Delay • 1 s maximum Start Up Rise Time • 20 ms typical Hold Up Time • 20 ms minimum at full load and 115 VAC Line Regulation • ±0.
5% Load Regulation • ±1% Transient Response • 10% maximum deviation, recovering to less than 1% within 500 µs for 50% step load change at 0.
2 A/µs Ripple & Noise • 100 mV pk-pk maximum, measured with 20 MHz BW Overvoltage Protection • 12 V output: 16.
5-18 V, 24 V output: 29-31.
2 V, 48 V output: 57.
6-62.
4 V Overload Protection • 110-150% of rated current, constant current limit Short Circuit Protection • Trip and restart (hiccup mode) Temperature Coefficient • ±0.
02%/°C General Efficiency Isolation Switching Frequency Signals MTBF • See table • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground • DRS80 60-300 kHz variable DRS120 & DRS240 100 kHz typical PFC & main converter • DRS120 & 240: DC OK Volt free contacts • >200 kHrs to MIL HDBK217F Environmental Operating Temperature • -20 ºC to +70 ºC (see derating curves) Cooling • Natural covection Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -25 °C to +85 °C Shock • IEC68-2-6, 30 g, 11ms half sine, 3 times in each of 6 axes Vibration • IEC68-2-27, 10-500 Hz, 2 g 10 mins/sweep.
...