TDK
Part Number B84243A8008W000
Manufacturer TDK
Description EMC filters
Published Mar 18, 2015
Detailed Description EMC filters 3-line filters for converters and power electronics Series/Type: Date: B84243A March 2015 © EPCOS AG 2015...
Datasheet PDF File B84243A8008W000 PDF File

B84243A8008W000
B84243A8008W000


Overview
EMC filters 3-line filters for converters and power electronics Series/Type: Date: B84243A March 2015 © EPCOS AG 2015.
Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
3-line filters for converters and power electronics Power line filters for 3-phase systems Rated voltage VR: 305/530 V AC Rated current IR: 3 A to 60 A Construction 3-line filters Metal case Features Low leakage current Typical performance according to EN 61800-3: C1 up to 25 m respectively C2 up to 50 m motor cable length Discharge time up to 44 A types: < 60 V within 1 s Short Circuit Current Rating SCCR 100 kA Degree of protection: IP 201) ENEC, UL and cUL approval pending Typical applications Frequency converters for motor drives, e.
g.
 elevators  pumps  conveyor systems  HVAC systems (heating, ventilation and air conditioning) Power supplies Textile machines, packaging machines, machine-tools Up to 44 A: Plug connected devices Terminals Finger-safe terminal blocks Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum data on packaging: Manufacturer's logo, ordering code, quantity, date code B84243A 1) According to IEC 60529 Please read Cautions and warnings and Important notes at the end of this document.
Page 2 of 11 3-line filters for converters and power electronics Typical circuit diagram B84243A Technical data and measuring conditions Rated voltage VR [L-PE / L-L] Rated current IR Test voltage Vtest Overload capability (thermal) Leakage current lLK MTBF at VR, TR Climatic category (IEC 60068-1) Approvals 305/530 V AC (50/60 Hz) Referred to 50 °C/40 °C rated temperature 1700 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) 1.
5  IR for 3 min per hour or 2.
5  IR for 30 s per hour At VR and 50 Hz > 300000 h 25/100/21 (25 °C/+100 °C/21 days damp heat test) IE...