DatasheetsPDF.com

YAS1012

Cosel
Part Number YAS1012
Manufacturer Cosel
Description AC-DC Power Supplies PCB Mount type
Published Apr 17, 2015
Detailed Description AC-DC Power Supplies PCB Mount type Ordering information YAS10 YA S 10 05 E 12345 1Series name R 2Single output 3Out...
Datasheet PDF File YAS1012 PDF File

YAS1012
YAS1012


Overview
AC-DC Power Supplies PCB Mount type Ordering information YAS10 YA S 10 05 E 12345 1Series name R 2Single output 3Output wattage 4Output voltage 5UL recognized,TuV approved CSA certified:E MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT YAS1005 10.
0 5V 2.
0A YAS1012 10.
8 12V 0.
9A SPECIFICATIONS MODEL YAS1005 YAS1012 VOLTAGE[V] CURRENT[A] AC85 - 264 1f or DC110 - 370 ACIN 200V 0.
14typ (Io=100%) INPUT FREQUENCY[Hz] 47 - 440 or DC EFFICIENCY[%] 70typ ACIN 100V 20typ (Io=100%) INRUSH CURRENT[A] ACIN 200V 40typ (Io=100%) 72typ VOLTAGE[V] 5 12 CURRENT[A] 2 0.
9 LINE REGULATION[mV] 20max 48max LOAD REGULATION[mV] 40max 100max RIPPLE[mVp-p] *1 80max YA OUTPUT RIPPLE NOISE[mVp-p] *1 120max 120max 150max TEMPERATURE REGULATION[mV] 0 to +55C 50max 150max OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed OUTPUT VOLTAGE SETTING[%] t5max (Rated input/output, Ta=25 C) HOLD-UP TIME[ms] 10typ (ACIN 85V, Io=100%) PROTECTION CIRCUIT OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MWmin (At Room Temperature) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current=100mA, DC500V 50MWmin (At Room Temperature) OPERATING TEMP.
,HUMID.
AND ALTITUDE -10 to +70C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max STORAGE TEMP.
,HUMID.
AND ALTITUDE ENVIRONMENT VIBRATION -20 to +75C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.
0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 490.
3m/s2 (50G), 11ms, once each X, Y and Z axis SAFETY AND AGENCY APPROVALS NOISE REGULATIONS CONDUCTED NOISE UL60950-1, EN60950-1, EN50178, CSA C22.
2 No.
60950-1 Complies with IEC60950-1 Complies with FCC-B, VCCI-B, Additional capacitors required for meeting CISPR22-B, EN55022-B (External Fuse is required) *1 Measured by 20MHz oscilloscope.
* Parall...



Similar Datasheet