Detailed Description S-1003 Series www.sii-ic.com © Seiko Instruments Inc., 2013 MANUAL RESET BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME S...
Datasheet PDF File S-1003 PDF File

S-1003
S-1003


Overview
S-1003 Series www.
sii-ic.
com © Seiko Instruments Inc.
, 2013 MANUAL RESET BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING) HIGH-ACCURACY VOLTAGE DETECTOR Rev.
1.
0_00 The S-1003 Series is a high-accuracy voltage detector developed using CMOS technology.
The detection voltage is fixed internally with an accuracy of ±1.
0% (−VDET ≥ 2.
2 V).
It operates with current consumption of 500 nA typ.
The release signal can be delayed by setting a capacitor externally.
Delay time accuracy is ±15%.
Moreover, since the S-1003 Series includes the manual reset function, the reset signal can be also output forcibly.
Two output forms Nch open-drain output and CMOS output are available.
„ Features • Detection voltage: • Detection voltage accuracy: • Current consumption: • Operation voltage range: • Hysteresis width: • Manual reset function: • Delay time accuracy: • Output form: • Operation temperature range: • Lead-free (Sn 100%), halogen-free 1.
2 V to 5.
0 V (0.
1 V step) ±1.
0% (2.
2 V ≤ −VDET ≤ 5.
0 V)...