DatasheetsPDF.com

85W Medical. LPS54-M Datasheet

DatasheetsPDF.com

85W Medical. LPS54-M Datasheet






LPS54-M Medical. Datasheet pdf. Equivalent




LPS54-M Medical. Datasheet pdf. Equivalent





Part

LPS54-M

Description

AC-DC / 10W - 85W Medical



Feature


Embedded Power for Business-Critical Con tinuity LPS50-M Series 60 Watts Total Power: Input Voltage: # of Output s: 55 - 60 Watts 90 - 264 VAC 127 - 30 0 VDC Single Rev. 1.08.09_149 LPS50-M Series  of 3 Special Features • Med ical Safety Approvals • Universal inp ut • Less than 1U high • 2” x 4 footprint • Remote sense • Overlo ad and short circuit protection • .
Manufacture

Emerson

Datasheet
Download LPS54-M Datasheet


Emerson LPS54-M

LPS54-M; Adjustable output voltage • High effic iency • High MTBF • Built in EMI fi lter (CISPR 22 Class B) • LED power g ood indicator • Input power < 74 watt s • Complies with EN61000 -3-2 • UL Class I approved • LPX50 enclosure k it available • Dual AC fuses Electri cal Specifications Input Input ra­nge: Frequency: Inrush current: Input power : Efficiency: EMI/RFI: Safety ground .


Emerson LPS54-M

leakage current: 90 - 264 VAC (wide rang e) 127-300 Vdc 47-440 Hz < 60 A peak @ 230 VAC, cold start @ 25°C < 74 Watts 80% - 85% typical at full load FCC Clas s B conducted; CISPR 22 Class B conduct ed; EN55022 Class B conducted, VDE0878P T3 Class B conducted 275uA @ 50/60 Hz; 264 VAC input Output Maximum power: Ad justment range: Hold-up time: Overload protection: 60W for.


Emerson LPS54-M

convection (LPS52, 55 W) ±20% minimum 10/20 ms 115/230 VAC input line Short circuit protection on all outputs. Case overload protected @ 110-160% of norma l rating Overvoltage protection: 30-50 % above nominal output Safety • UL: • CSA: • VDE: • CE: UL 60601- 1 CSA-C22.2 No. 601.1-M90 EN60601-1 LVD & EMC Remote sense: Compensatesd for 0.5 V lead drop max. Will .

Part

LPS54-M

Description

AC-DC / 10W - 85W Medical



Feature


Embedded Power for Business-Critical Con tinuity LPS50-M Series 60 Watts Total Power: Input Voltage: # of Output s: 55 - 60 Watts 90 - 264 VAC 127 - 30 0 VDC Single Rev. 1.08.09_149 LPS50-M Series  of 3 Special Features • Med ical Safety Approvals • Universal inp ut • Less than 1U high • 2” x 4 footprint • Remote sense • Overlo ad and short circuit protection • .
Manufacture

Emerson

Datasheet
Download LPS54-M Datasheet




 LPS54-M
Embedded Power for
Business-Critical Continuity
LPS50-M Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
55 - 60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Rev. 1.08.09_149
LPS50-M Series
 of 3
Special Features
• Medical Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
protection
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
(CISPR 22 Class B)
• LED power good indicator
• Input power < 74 watts
• Complies with EN61000 -3-2
• UL Class I approved
• LPX50 enclosure kit available
• Dual AC fuses
Safety
UL: UL 60601-1
CSA: CSA-C22.2 No. 601.1-M90
VDE: EN60601-1
CE: LVD & EMC
Electrical Specifications
Input
Input ra­nge:
90 - 264 VAC (wide range) 127-300 Vdc
Frequency:
47-440 Hz
Inrush current:
Input power:
Efficiency:
< 60 A peak @ 230 VAC, cold start @ 25°C
< 74 Watts
80% - 85% typical at full load
EMI/RFI:
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B
conducted, VDE0878PT3 Class B conducted
Safety ground leakage 275uA @ 50/60 Hz; 264 VAC input
current:
Output
Maximum power:
60W for convection (LPS52, 55 W)
Adjustment range:
±20% minimum
Hold-up time:
10/20 ms 115/230 VAC input line
Overload protection:
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Overvoltage protection: 30-50% above nominal output
Remote sense:
Compensatesd for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.




 LPS54-M
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C.
-20 °C start up
Storage temperature:
-40 °C to +85 °C
Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Operating; non-condensing 10% to 95% RH
Vibration:
IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated:
> 550,000 hours at full load and 25 °C ambient conditions
Mechanical Drawing
GND
VR1
Output Voltage
M1 Adjust pot M2
GRN/
YEL
+
TP1
~~
DB1
L3
R3A
C32
R3
T1 D4
F1
11
3
SK1
T3.15A 2.5A
250VAC
L1
C5
F2 C1
TH1
2005
R22
C18 C9
C17
Q5
R1
C4
VR1 L2
TP2
J4
C24 C27
SK2
1C30
C22
A
B T2
EF
J1 J2
Q6 I
GH
D2
J3J
6
HTSK_SEC
D
LED1
3.75"
[95.3]
4.00"
[101.6]
Mounting Hole
Ø0.16"[4.0] 4 Places
Max. Screw Head
Diameter .22” (5.6)
Rev. 1.08.09_149
LPS50-M Series
 of 3
0.197” (5.0) Minimum Standoff Height
0.16"
[4.0]




 LPS54-M
Embedded Power for
Business-Critical Continuity
Ordering Information
Model
Number
Output
Voltage
Minimum Maximum Load with
Load Convection Cooling
Peak
Load1
Regulation2
Ripple P/P
(PARD)3
LPS52-M
5V 0A
11 A 12 A ±2% 50 mV
LPS53-M
12 V 0 A
5 A 5.4 A ±2% 120 mV
LPS54-M
15 V 0 A
4 A 4.4 A ±2% 150 mV
LPS55-M
24 V 0 A
2.5 A
2.75 A
±2%
240 mV
LPS58-M
48 V 0 A
1.25 A
1.35 A
±2%
480 mV
1. Peak current lasting < 15 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and
load ranges.
Pin Assignments
Connector LPS52-M
SK1-1
SK1-3
Line
Neutral
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
+5 V
+5 V
Common
Common
-Sense
+Sense
LPS53-M
Line
Neutral
+12 V
+12 V
Common
Common
-Sense
+Sense
LPS54-M
Line
Neutral
+15 V
+15 V
Common
Common
-Sense
+Sense
LPS55-M
Line
Neutral
+24 V
+24 V
Common
Common
-Sense
+Sense
LPS58-M
Line
Neutral
+48 V
+48 V
Common
Common
-Sense
+Sense
Mating­ Connectors
AC Input: Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-52-0113
DC Outputs: Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
Emerson Network Power Connector Kit #70-841-006, includes all of the above
Notes:
1. Specifications subject to change without notice.
­2. All dimensions in inches (mm), tolerance is ±0.02”­­ (±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise
stated.
6. Warranty: 2 year
7. Weight: 0.41lbs/0.18kg
Rev. 1.08.09_149
­Americas
5810 Van Allen Way
LPS50-M Series
 of 3
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.






Recommended third-party LPS54-M Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)