MAP130

Power-One
Part Number MAP130
Manufacturer Power-One
Description Automatic 115/230 Input Voltage Selection
Published Apr 27, 2005
Detailed Description MAP130 SERIES Power-One’s MAP130 series of single and multiple output power supplies provide fully regulated outputs wit...
Datasheet PDF File MAP130 PDF File

MAP130
MAP130


Overview
MAP130 SERIES Power-One’s MAP130 series of single and multiple output power supplies provide fully regulated outputs with high-peak current capabilities in a compact 4.
50" x 8.
50" x 2.
00" U-channel chassis.
Other standard features include autoselect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts.
FEATURES • Automatic 115/230 Input Voltage Selection • All Outputs Fully Regulated • Remote Sense, Overvoltage Protection, and Overtemperature Protection • Power Fail Signal Included • Greater than 100,000 Hour MTBF • U-Channel Chassis: 8.
50" x 4.
50" x 2.
00" (215.
9mm x 114.
3mm x 50.
8mm) • Optional Cover • Metric and SAE Mounting Inserts SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE CONTINUOUS CURRENT PEAK CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 1) ACCURACY This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 degrees C.
All products are approved to the latest international regulatory standards, and display the CE Mark.
MAP130-1005 MAP130-1012 MAP130-1024 5V 12V/15V 24V/28V 4.
75V to 5.
50V 11.
4V to 15.
75V 22.
5V to 30.
0V 26A 12A/10A (Note 2) 6.
2A/5.
4A (Note 2) 30A 13.
8A/11A 6.
8A/5.
9A 0.
2% 0.
2% 0.
2% 1% 1% 1% 1% 1% 1% 5.
1V to 5.
2V 12.
0V to 12.
2V 23.
9V to 24.
1V NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP130-1012 output currents are expressed as 12V/15V operation.
MAP130-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
MULTIPLE OUTPUT MODEL SELECTION CHART – 130W CONTINUOUS OUTPUT POWER MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 2) ACCURACY MAP130-4000 MAP130-4001 MAP130-4002 +5V +1...