DatasheetsPDF.com

MAP140

Power-One
Part Number MAP140
Manufacturer Power-One
Description Universal Input 85-264 VAC
Published Apr 27, 2005
Detailed Description MAP140 SERIES Power-One’s MAP140 series provides a full range of options and up to 30 watts more power than comparable p...
Datasheet PDF File MAP140 PDF File

MAP140
MAP140


Overview
MAP140 SERIES Power-One’s MAP140 series provides a full range of options and up to 30 watts more power than comparable products in this industry standard footprint.
With a universal input from 85 to 264 VAC and power densities up to 2.
6 watts/inch3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems.
FEATURES • Universal Input 85-264 VAC • Input Transient & ESD Compliance to EN61000-4-2/-3/-4 • CE Marked to Low Voltage Directive • Industry Standard Footprint: 7.
00" x 4.
30" x 1.
80" (177.
8mm x 109.
2mm x 45.
7mm) • Remote Sense and Overvoltage Protection • Power Fail Signal Standard on MAP140-3000P, Optional on MAP140-1012 and MAP140-1024 • Optional Overtemperature Protection, L-Bracket, and Cover.
SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT FORCED AIR CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY Rated for use in convection and forced air cooled (200 LFM) applications, the MAP140 delivers dependable power with a Mean Time Before Failure (MTBF) in excess of 180,000 hours.
In addition to UL, CSA, and TÜV regulatory compliance, the MAP140 displays the CE Mark.
MAP140-1012 MAP140-1024 MAP140-1048 12V/15V 24V/28V 48V 11.
0V to 16.
0V 22.
8V to 29.
2V 45.
6V to 54.
0V 9.
2/7.
3A (Note 2) 4.
6/4A (Note 2) 2.
3A 12.
5A/10A (Note 2) 6.
3A/5.
4A (Note 2) 3.
1A 0.
1% 0.
1% 0.
1% 0.
5% 0.
5% 0.
5% 1% 1% 1% 11.
97V to 12.
03V 23.
95V to 24.
05V 47.
9V to 48.
1V NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP140-1012 output currents are expressed as 12V/15V operation.
MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 140W FORCED AIR COOLED (200 LFM) MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPP...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)