DatasheetsPDF.com

C5310

Vectron International
Part Number C5310
Manufacturer Vectron International
Description VCXO Surface Mount Package Reflow Process Compatible AT-Cut Crystal
Published Oct 27, 2006
Detailed Description www.DataSheet4U.com C5310 Typical Applications Base Stations Test Equipment Switching Portable Equipment VCXO Feature...
Datasheet PDF File C5310 PDF File

C5310
C5310


Overview
www.
DataSheet4U.
com C5310 Typical Applications Base Stations Test Equipment Switching Portable Equipment VCXO Features Surface Mount Package Reflow Process Compatible AT-Cut Crystal Previous Vectron Model Numbers Frequency range Standard frequencies SVO50; SVO100; SVO110 1 MHz – 700 MHz 16.
384; 30.
720; 32.
768; 38.
880 MHz; 51.
840; 52.
00; 68.
736; 77.
760; 155,52; 622,08 MHz Frequency stabilities1 [Frequency < 80 MHz] Parameter vs.
operating temperature range (Referenced to +25°C) Parameter Initial tolerance vs.
supply voltage change vs.
load change vs.
aging /1.
Year vs.
aging / year (followingYears) Min -15.
0 Min -10.
0 -3.
0 -1.
0 -3.
0 -1.
0 Typ Typ Max.
+15.
0 Max.
+10.
0 +3.
0 +1.
0 +3.
0 +1.
0 Units ppm Units ppm ppm ppm ppm ppm Operating temp range -20 … +70°C Ordering Code D105 5 Condition @vc=Vs/2 fo < 80 MHz VS ± 5% Load ± 10% fo < 80 MHz Frequency stabilities1 [Frequency > 80 MHz] Parameter vs.
operating temperature range (Referenced to +25°C) Parameter Initial tolerance vs.
supply voltage change vs.
load change vs.
aging /1.
Year vs.
aging / year (followingYears) Min -30.
0 Min -15.
0 -3.
0 -2,0 -3.
0 -1.
0 Typ Typ Max.
+30.
0 Max.
+15.
0 +3.
0 +2.
0 +3.
0 +1.
0 Units ppm Units ppm ppm ppm ppm ppm Operating temp range -40 … +85°C Ordering Code F305 5 Condition @vc=Vs/2 fo > 80 MHz VS ± 5% Load ± 10% fo > 80 MHz Supply voltage Parameter Supply voltage (Vs) Current consumption Current consumption Supply voltage (Vs) Current consumption Current consumption Current consumption Min 4.
75 Typ 5.
0 Max.
5.
25 40 90 3.
465 30 80 25 Units VDC mA mA VDC mA mA mA Condition Ordering Code SV050 @ HCMOS @ PECL SV033 @ LVHCMOS @ LVPECL @ LVDS 5 3.
135 3.
3 RF output Parameter Signal Load Rise and Fall time Duty cycle Signal Load Rise and Fall time Duty cycle Signal Load Rise and Fall time Duty cycle Vectron International · www.
vectron.
com Vectron International Headquarters 267 Lowell Road Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC.
100 ...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)