DatasheetsPDF.com

DS1200-3

Emerson
Part Number DS1200-3
Manufacturer Emerson
Description AC-DC / Distributed Power Front-End 1U
Published Oct 25, 2009
Detailed Description Embedded Power for Business-Critical Continuity DS1200 1200 Watts Distributed Power System Distributed Power Bulk Front...
Datasheet PDF File DS1200-3 PDF File

DS1200-3
DS1200-3


Overview
Embedded Power for Business-Critical Continuity DS1200 1200 Watts Distributed Power System Distributed Power Bulk Front-End Total Output Power: 1200 Watts +3.
3 Vdc Stand-by Output Wide Range Input Voltage: 90 - 264 Vac Rev.
9.
10.
09_22 DS1200  of 4 Electrical Specifications Special Features • Active power factor correction • EN61000-3-2 harmonic compliance • Active AC inrush control • 1U X 2U form factor • 21.
71 W / in3 • +12 Vdc Output • +3.
3 Vdc stand-by (5 V standby - consult factory) • No minimum load required • Hot plug operation • N + 1 redundant • Internal OR’ing fets • Active current sharing (10 - 100% load) • Built-in cooling fan (40 mm x 28 mm) • I2C communication interface bus • PMBus compliant • EERPOM for FRU data • Red/green bi-color LED status • Internal fan speed control • Fan Fail Tach Output Signal • INTEL, SSI Std.
logic timing • INTEL, SSI Std.
FRU data format • Full digital control • One year warranty Input Input ra­nge: Frequency: Inrush current: Efficiency: Conducted EMI: Radiated EMI: Power factor: Leakage current: Hold up time: 180 - 264 (1200 W) 90 - 264 (1000 W) 47-63 Hz, single phase AC 40 Apk maximum inrush current > 91% typical at high line 50% load FCC Subpart J EN55022 Class B FCC Subpart J EN55022 Class B 0.
99 typical 1.
40 mA @ 240 VAC 12 ms minimum +12 V @ 100 A (high line) +12 V @ 81.
6 A (low line) +3.
3 Vsb @ 6 A (5 V @ 4 A available) ±5% on +12V only using I2C +12 Vdc; +5% / -5% +3.
3 Vsb; +5% / -5% +12 Vdc; latches off if overcurrent lasts over 1 second, otherwise it is auto recovery (See Table 1 next page) +3.
3 Vsb, 9 A max (hiccup mode) +12 Vdc; 13.
2 - 14.
4 Vdc +3.
3 Vsb; 3.
76 - 4.
30 Vdc +12 Vdc; 9 - 10.
8 V (latch off) 2 second max, 5 - 50 mS, monotonic rise 5 - 50 mS, monotonic rise Output Main DC voltage: Stand-By: Adjustment range: Regulation: Over current: Over voltage: Under voltage: Turn-on delay: Main output rise time: Safety • UL/cUL 60950 (UL Recognized) • NEMKO+ CB Report EN60950 • EN60950 • CE Mark • China CCC ...